Technical Bulletin
No. RTB-002
SUBJECT: Point to Point Diagram Correction
DATE: Jan. 15, ’91
PAGE: 1 of 2
PREPARED BY: M. Kitajima
CHECKED BY:
FROM: Copier Technical Support Section
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
Revision of service manual
Information only
Other
MODEL: F40
Please correct your point to point diagram as follows:
1) Location on Copier P to P: G4
INCORRECT
CORRECT
NOTE:
RA2 is closed.
2) Location on Copier P to P: C5
The signal description is "Fusing Exit Sensor".
Cleaning Heater
Drum Heater
Anticondensation Heater
(H) CN701-2
(H) CN672-2
(H) CN609-2
(W) T19
CN672-1 (B)
CN609-1 (B)
CN701-1 (B)
T20
Cleaning Heater
Drum Heater
Anticondensation Heater
(H) CN701-2
(H) CN672-2
(H) CN609-2
(W) T19
CN672-1 (B)
CN609-1 (B)
CN701-1 (B)
T20
RA2
CN102-B5 (R)
CN102-B4 (T)
CN101-A20 (H)
CN102-A13 (G)
CN101-B18 (G)
CN101-A18 (C)
CN655-2
CN687-2
CN688-2
CN655-2 (W)
CN687-2 (W)
CN688-2 (W)
CN101-B7 (C)
Fusing
Cooling
Fan M
Toner
Supply
MC
Cleaning
SOL
VC [5]
C-GND [0]
Cleaning SOL [ 24]
Toner
Supply MC [ 24]
Fusing
Exit Sensor [ 5]
Fusing Cooling
Fan Motor [ 24]
Fusing
Unit Set [0]