281
7
Chapter 7 Troubleshooting Guide
(27) “E016” is displayed
Procedures Cause/Detective section Items to be checked
Result Countermeasure
1
Is the feed tray properly attached?
NO Properly attach the feed tray.
2
Does the horizontal registration motor
rotate when checked using HELP-015
YES Follow the procedure 7.
3
Fuse
Is the fuse(F1) of the drive PCB
unit normal?
NO Replace the fuse.
4
Horizontal registration
motor
Measure the voltage between CN6-
8 and CN6-9 of the drive PCB unit
when the horizontal registration
motor is activated using HELP-015.
Is it +24V or -24V?
YES
Check the wiring harness. If
there is no problem, replace the
horizontal registration motor.
5
24V power supply
Measure the voltage between
CN51-5 (+24) and CN51-1 (GND)
of the 24V power supply with a
tester. Is it +24V?
NO
Measure the voltage between CN1-
1 and CN1-3 of the 24V power
supply with a tester. If it is AC100V,
replace the 24V power supply.
6
Drive PCB unit
Does replacing the drive PCB unit
solve the problem?
YES Finish
Main PCB unit
NO
Check the connector and bundled
wire between CN1 of the drive PCB
unit and CN19 of the main PCB unit.
If OK, replace the main PCB unit.
7
Do the horizontal registration
encoder sensor and the horizontal
registration center sensor work
properly when checked using
HELP-015?
NO
Follow the procedure 8 when the
horizontal registration encoder
sensor is defective.
Follow the procedure 9 when
the horizontal registration center
sensor is defective.
8
Horizontal registration
encoder sensor
Measure the voltage with a tester
when turning the horizontal
registration encoder sensor on and
off. Is it normal?
NO Replace the horizontal
registration encoder sensor.
Main PCB unit
YES
Check the wiring harness. If there
is no problem, replace the main
PCB unit.
9
Horizontal registration
center sensor
Measure the voltage with a tester
when turning the horizontal
registration center sensor on and
off. Is it normal?
NO Replace the horizontal
registration center sensor.
Main PCB unit
YES
Check the wiring harness. If there
is no problem, replace the main
PCB unit.
(28) “E017” is displayed (
ADF
)
Procedures Cause/Detective section Items to be checked
Result Countermeasure
1
Are all the wiring harnesses
of the main PCB unit securely
connected?
NO Securely connect all the
connectors of the main PCB unit.
Main PCB unit
YES Replace the main PCB unit.
1
Содержание DD 5450
Страница 1: ...RICOH DD5450 DD5440 Machine Code C284 C283 Field Service Manual June 2016...
Страница 2: ......
Страница 15: ...Chapter 1 Dimensions 13 2 Dimensions 2 622 1405 555 228 1080 710 980 688 370 Unit mm...
Страница 37: ...35 Chapter 2 Machine Installation 5 Touch OK DATE TIME is set 6 Touch END 1...
Страница 170: ......
Страница 262: ......