T
echnical
B
ulletin
PAGE: 1/2
Model: LCIT RT5030 (D452
)
Date:
21-Aug-09
No.:
RD452001
Subject: Service Manual Correction: CIS Image
Position Adjustment
Prepared by: M. Abe
From: PPMC Service Planning Department 1G
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other ( )
Tier2
Please apply the following 2 corrections concerning the CIS Image Position Adjustment to
your service manual.
Location of the Incorrect Description 1
Replacement and Adjustment > Adjustment > Adjusting Image Position Sensor Strength
and Side-To-Side Registration; step 6
Incorrect Description 1
Do SP1909 -2 (CIS Image Position Adjustment: PWM After Adjustment - LCIT).
•
If the displayed value is between
10 (Ah) and 40 (28h)
, the CIS is calibrated
successfully. (The display is in hexadecimal code.)
•
If the value is outside this range, do SP 1910 -2 and 1909 -2 again. If the value
does not come between
20 and 40
, the CIS may be defective.
Correction
Do SP1909 -2 (CIS Image Position Adjustment: PWM After Adjustment - LCIT).
•
If the displayed value is between
Ah (10) and 28h (40)
,
the CIS is calibrated
successfully. (The display is in hexadecimal code.)
•
If the value is outside this range, do SP 1910 -2 and 1909 -2 again. If the value
does not come between
Ah and 28h
, the CIS may be defective.
NOTE: Value is displayed in hexadecimal code on the operation panel. Values shown in
brackets are decimal code for reference.