Ricoh B867 Скачать руководство пользователя страница 1

 

 

 

 

PRINTER/SCANNER UNIT 

B867 

Содержание B867

Страница 1: ...PRINTER SCANNER UNIT B867...

Страница 2: ......

Страница 3: ...N IEEE 802 11B INSTALLATION 10 1 2 5 IEEE 1284 INSTALLATION 12 1 2 6 BLUETOOTH INSTALLATION 13 1 2 7 USB HOST INSTALLATION 14 1 2 8 REMOTE COMMUNICATION GATE INSTALLATION 15 2 REPLACEMENT AND ADJUSTME...

Страница 4: ...IRMWARE UPDATE PROCEDURE 120 4 5 7 NVRAM DATA UPLOAD DOWNLOAD 126 4 5 8 POWER ON SELF TEST 127 5 DETAILED SECTION DESCRIPTIONS 128 5 1 OVERVIEW 128 5 2 CONTROLLER FUNCTIONS 130 5 2 1 PAPER SOURCE SELE...

Страница 5: ...2 5 7 2 USB 1 1 2 0 142 5 7 3 USB CONNECTORS 143 5 7 4 PIN ASSIGNMENT 143 6 SPECIFICATIONS 145 6 1 GENERAL SPECIFICATIONS 145 6 1 1 PRINTER 145 6 1 2 SCANNER 146 6 2 SOFTWARE ACCESSORIES 147 6 2 1 PRI...

Страница 6: ......

Страница 7: ...l to avoid touching those components with your bare hands Health Safety Conditions Toner and developer are non toxic but if you get either of them in your eyes by accident it may cause temporary eye d...

Страница 8: ...ervice depot when replacement of the optical subsystem is required Use of controls or adjustment or performance of procedures other than those specified in this manual may result in hazardous radiatio...

Страница 9: ...nor injuries Obey these guidelines to avoid problems such as misfeeds damage to originals loss of valuable data and to prevent damage to the machine Always obey these guidelines to avoid serious probl...

Страница 10: ......

Страница 11: ...e for the GW controller box and printer scanner option 1 1 1 ACCESSORY CHECK No Description Q ty 1 Installation procedure 1 2 Controller box 1 3 Operation panel 1 4 Expansion decal 1 5 Screw M3 x 8 1...

Страница 12: ...B867 2 SM 1 1 2 INSTALLING EXPANSION COMPONENT Unplug the machine power cord before starting the following procedure Step 1 Controller Box 1 Remove the rear cover A x 6 2 Remove the slot cover B x 1...

Страница 13: ...not damaged F and that the three openings G H I hold the controller box 5 Fasten the screws x 7 including the screw C 6 Remove the FCU cover J x 3 Step 2 Printer Scanner 1 Remove the controller box c...

Страница 14: ...cm 3 2 from the end of the cable G 7 Install the ground cable H as shown and then clamp the cable x 2 x 1 8 Release the clamps I and then bind the harness J with the clamp K 9 Attach the clamp K to t...

Страница 15: ...roller box for the USA model only If installing fax option go to fax installation step now Step 4 Reassembling 1 Reassemble the controller box 2 Install the rear cover 1 1 3 INSTALLING PANELS AND KEYS...

Страница 16: ...on 6 Start the SP mode 7 Select SP5 801 001 and initialize the all SP data 8 Exit the SP mode and then start the UP mode 9 Select the Remote Service User Tool System Settings Administrator Tools Exten...

Страница 17: ...Controller Box and Printer Scanner SM 7 B867 B867 Printer Scanner Unit 19 Specifies the date and time with Set Date or Set Time User Tool System Settings Set Date or Set Time...

Страница 18: ...connections and applications I F Card Slot Slot A is used for one of the optional I F connections IEEE1284 IEEE802 11 Wireless LAN Bluetooth or Embedded RCG M Slot B do not use SD Card Slot Slot 1 is...

Страница 19: ...3 SD card into the slot 2 B 3 Reinstall the SD card slot cover A x 1 4 Turn on the main power switch 5 Print out the configuration page User Tools Counter Printer Features List Test Print and then che...

Страница 20: ...ll be installed automatically 4 Reattach the slot cover A x 1 IMPORTANT Do not remove the VM option SD card after installation Keep the SD card in slot 3 For third vendor Java based SDK applications y...

Страница 21: ...ures List Test Print and then check that this device is detected If reception is poor you may need to move the machine Make sure that the machine is not located near an appliance or any type of equipm...

Страница 22: ...elect Used to select the WEP key Default 00 5840 018 SSID Check Used to check the SSID 5840 020 WEP Mode Used to display the maximum length of the string that can be used for the WEP Key entry 1 2 5 I...

Страница 23: ...ain power switch 4 Print out the configuration page User Tools Counter Printer Features List Test Print and then check that this device is detected 1 2 6 BLUETOOTH INSTALLATION Component Check No Desc...

Страница 24: ...the Bluetooth card 4 Install the Bluetooth card in the wireless adaptor 5 Attach the antenna cap to the Bluetooth card 6 Turn on the main power switch 7 Print out the configuration page User Tools Co...

Страница 25: ...e main power switch 4 Print out the configuration page User Tools Counter Printer Features List Test Print and then check that this device is detected 5 Exit the User Tools mode 1 2 8 REMOTE COMMUNICA...

Страница 26: ...terface slot A B x 2 3 Confirm the following SP settings before starting installation flow SP5 985 001 On Board NIC is set to 0 OFF SP5 816 150 To Select the country SP5 816 154 To set an outside conn...

Страница 27: ...Controller Options SM 17 B867 B867 Printer Scanner Unit...

Страница 28: ...Mechanical components may stop out of their home positions if you turn off the main power switch while they are operating The component may be damaged if you try to remove it when it is not in the hom...

Страница 29: ...x 6 2 Remove the FCU cover B x 3 3 Remove the SD card cover C x 1 and then remove all SD cards in the SD slots 4 Remove the controller box cover E x 7 5 Remove the RAM DIMM F if it has been installed...

Страница 30: ...Remove the controller board with the rails H x 5 8 Release the hooks I and then pull out the rails J 9 Controller board When replacing the controller board remove the NVRAMs from the board Install the...

Страница 31: ...re correctly installed 2 The mark B on the NVRAM should be directed to the right side seem from the back side of the machine 3 Reassemble the machine 4 Copy the old NVRAM data to the new NVRAM with SP...

Страница 32: ...er switch off and on Turn the main power switch off and on C The main machine can be operated as usual excluding the unit related to the service call Turn the main power switch off and on D The SC his...

Страница 33: ...frame No normal end signal returns This symptom happens three times Defective or broken line between machine and device MF accounting device error 2 633 C The machine is communicating with the accoun...

Страница 34: ...expanded authentication module is not correct 1 Install the correct file of the expanded authentication module 650 Communication error of the remote service modem Embedded RCG M Authentication error 0...

Страница 35: ...p connection Program parameter error 001 D The unexpected error occurs when the modem Embedded RCG M tries to call the center with a dial up connection Software bug Program execution error 002 D Same...

Страница 36: ...oard 1 Check the setting of SP5875 001 If the setting is set to 1 OFF change it to 0 ON SC8xx No Definition Symptom Possible Cause Countermeasure Watchdog error 818 B While the system program is runni...

Страница 37: ...lot 1 lowest slot Defective controller Software error 1 Check and or replace the RAM DIMM 2 Check and or replace the SD card in slot 1 lowest slot 3 Replace the controller See NOTE at the end of the S...

Страница 38: ...am 3 Replace the controller board 0601 0602 0605 0606 0607 0609 Detailed error code B Exceptional command does not operate even though it is executed on purpose Defective CPU devices 1 Replace the con...

Страница 39: ...write the data in the only cache of memory the data is actually written in another area not cache of memory Defective CPU devices Incorrect SPD Boot mode setting error 1 Replace the controller board 2...

Страница 40: ...is displayed System firmware problem Defective RAM DIMM Defective controller Reinstall the controller system firmware 1 Replace the RAM DIMM 2 Replace the controller board 823 Self diagnostic Error NI...

Страница 41: ...battery discharged 1 Replace the NVRAM with another NVRAM with an RTC device 15FF RTC not detected 826 B The RTC device is not detected NVRAM without RTC installed Backup battery discharged 1 Replace...

Страница 42: ...orrect this SC code is displayed Defective ROM DIMM 1 Replace the ROM DIMM 829 Self diagnostic Error Optional RAM Verification error Slot 1 0401 C The data stored in the RAM in Slot 1 does not match t...

Страница 43: ...tooth card is not recognized Loose connection between the wireless card and the connection board Wireless card access error 854 C The machine has been reading the data from the card The machine loses...

Страница 44: ...or 13 to 3 File system error other number Device error 868 B An error report is sent from the SD card reader SD card not inserted correctly SD card defective Controller board defective 1 For a file sy...

Страница 45: ...necessary font is not found in the SD card when the printer application starts A necessary font is not found in the SD card The SD card data is corrupted 1 Check that the SD card stores correct data S...

Страница 46: ...operation panel does not start or ends abnormally Software for that application is defective An option required by the application RAM DIMM board is not installed Too complicated nest of the fax grou...

Страница 47: ...e the platen cover or ARDF is open while the main unit is communicating with a facsimile or the network server or while the machine is accessing the memory for reading or writing data 4 1 1 ENABLING A...

Страница 48: ...Step SSP Consult your supervisor before you use this program 4 2 1 SP4 XXX MODE 4921 Image Adj Selection Copy 0 to 10 0 1 001 Selects which mode the settings from SP4 922 to SP4 932 are used for 0 No...

Страница 49: ...age processing modes of SP4 921 001 Copy 002 Fax 003 Scanner 1 Light 0 Normal 1 Dark Texture Removal 4926 Adjusts the texture removal level that is used with error diffusion 0 The default value for ea...

Страница 50: ...nt Dot Erase 4928 Selects the dot erase level Higher settings provide greater erasure This setting is only applied to the originals in SP4 921 001 Copy 002 Fax 003 Scanner 2 to 2 0 1 step Positive Neg...

Страница 51: ...t the clarity This setting is only applied to the originals in SP4 921 001 Copy 002 Fax 003 Scanner 4 2 2 SP5 XXX MODE 5001 All Indicators On 001 All LEDs turn on The LCDs turn on or off with ON or OF...

Страница 52: ...lay 001 Refill Toner CTL 0 or 1 0 0 ON 1 OFF 5055 Display IP address 001 Display IP address CTL Displays or does not display the IP address on the LCD 0 or 1 0 0 No 1 Yess 5056 Coverage Counter 001 Co...

Страница 53: ...n standard paper size using the UP mode 5113 Optional Counter Type 001 Optional Counter Type 1 CTL This program specifies the counter type 0 None 1 Key card RK 3 4 2 Key card down 3 to 10 Japan only 1...

Страница 54: ...21 Counter Up Timing CTL 0 Feed In 1 Exit 001 Selects whether the key counter increments at time of paper feed in or at time of paper exit 5127 APS Mode CTL 0 Not disabled 1 Disabled 001 This program...

Страница 55: ...rsion CTL Displays the NVRAM version in the controller board Set Time 5302 Adjusts the RTC real time clock time setting for the local time zone Examples For Japan 9 GMT enter 540 9 hours x 60 min DOM...

Страница 56: ...hour step 8th digit The length of the advanced time 0 to 5 10 minutes step For example 3500010 EU default The timer is advanced by 1 hour at am 0 00 on the 5th Sunday in March The digits are counted f...

Страница 57: ...install or uninstall the SDK application 201 SDK1 Certification Method CTL 0 to 255 0 1 step DFU 210 SDK2 Unique ID CTL DFU 211 SDK2 Certification Method CTL 0 to 255 0 1 step DFU 220 SDK3 Unique ID C...

Страница 58: ...ument misfeeds are not included 0 to 3 3 1 step 0 Zero Off 1 Low 2 5K jams 2 Medium 3K jams 3 High 6K jams 5505 Error Alarm 001 Sets the error alarm level The error alarm counter counts 1 when any SC...

Страница 59: ...utive paper jams Door Open 0 Disable 1 Enable 003 Enables disables initiating a call when the front door remains open Jam Remains Time 03 to 30 10 1 minute step 011 Sets the time a jam must remain bef...

Страница 60: ...ermines what happens if the door remains open 15 min Displays a warning if set to ON Pressing the call button will contact the service center SC Alarm Setting CTL 5515 With Remote in use these SP code...

Страница 61: ...er switch off and on after executing this SP SCS 003 Clears the system settings IMH 004 Clears IMH data DFU MCS 005 Clears MCS data DFU Copier 006 Clears the copy application settings Fax 007 Clears t...

Страница 62: ...rage file numbers Clear DCS Setting 014 Initializes the DCS Delivery Control Service settings Clear UCS Setting 015 Initializes the UCS User Information Control Service settings MIRS Setting 016 Initi...

Страница 63: ...rs and alphabetic characters can be input 5816 NRS Function CTL 001 I F Setting Selects the remote service setting 0 to 2 2 1 step 0 Remote service off 1 CSS remote service on 2 Remote service on 002...

Страница 64: ...sables access via port 80 to the SOAP method 0 or 1 0 0 Disabled 1 Enabled Function Flag 021 This SP displays the embedded RCG installation end flag 1 Installation completed 2 Installation not complet...

Страница 65: ...on and is not printed in the SMC report HTTP Proxy Port Number 064 This SP sets the port number of the proxy server used for communication between embedded RCG N and the gateway This setting is necess...

Страница 66: ...being sent to the GW URL 11 A rescue update for certification has been issued and a rescue certification setting is in progress for the rescue GW connection 12 The rescue certification setting is comp...

Страница 67: ...is no request for certification update in progress 1 Request for certification update in progress The current certification has expired 2 An SSL error notification has been issued after the certificat...

Страница 68: ...Remote certification Spaces are displayed as underscores _ Asterisks indicate that no Remote certification exists CERT Subject 090 Displays the common name of the Remote certification subject CN the...

Страница 69: ...nected as either dial up or push type so embedded RCG M can automatically distinguish the number that connects to the outside line The current progress success or failure of this execution can be disp...

Страница 70: ...e connection for embedded RCG M in a system that employs a PBX internal line If the execution of SP5816 151 has succeeded and embedded RCG M has connected to the external line this SP display is compl...

Страница 71: ...the line where embedded RCG M is connected This number is transmitted to and used by the Call Center to return calls Limit 24 numbers numbers only Ans Timing Adj 162 When the Call Center calls out to...

Страница 72: ...certification has been completed However embedded RCG M generates charges based on transmission time for the customer so a limit is placed upon the time allowed for these transactions If these transa...

Страница 73: ...is status the external RCG unit cannot answer a polling request 3 The registered device by the external RCG is being set In this status the embedded RCG device cannot be set 4 The registered module by...

Страница 74: ...ucceeded 2 Registration in progress 3 Proxy error proxy enabled 4 Proxy error proxy disabled 5 Proxy error Illegal user name or password 6 Communication error 7 Certification update error 8 Other erro...

Страница 75: ...f service 2390 Program out of service 2391 Two registrations for same device 2392 Parameter error 2393 External RCG not managed 2394 Device not managed 2395 Box ID for external RCG is illegal 2396 Dev...

Страница 76: ...1284 Compatibility 0 or 1 1 1 step 0 Disabled 1 Enabled 052 ECP Centro Enables or disables ECP Compatibility 0 or 1 1 1 step 0 Disabled 1 Enabled NOTE This SP is activated only when SP5 828 50 is set...

Страница 77: ...ink referenced on the Ethernet or wireless LAN 802 11b in the format Link Local Address Prefix Length The IPv6 address consists of a total of 128 bits configured in 8 blocks of 16 bits each 147 Active...

Страница 78: ...1 to 11 default 11 006 Sets the maximum number of channels available for data transmission via wireless LAN The number of channels available varies according to location The default settings are set f...

Страница 79: ...tification related 3 Address book related 4 Machine management related 5 Output related printing delivery 6 Repository related 001 This is a debugging tool It sets the debugging output mode of each Ne...

Страница 80: ...er recognized as the BCD Delivery Server Setting CTL 5845 Provides items for delivery server settings FTP Port Num 0 to 65535 3670 1 step 001 Sets the FTP port number used when image files to the Scan...

Страница 81: ...r of Scan Router This SP allows only the setting of the IP address without reference to the DNS setting Delivery Server Model 0 to 4 0 1 step 009 Allows changing the model of the delivery server regis...

Страница 82: ...the port number of the primary delivery server Srv URL Path Pri 015 Specifies the URL path of the primary delivery server Svr Schm Sec 016 Specifies the scheme of the secondary delivery server Svr Po...

Страница 83: ...erver is unstable After clearing the ID the ID will be established again automatically by cycling the machine off and on Maximum Entries 150 to 999 150 1 step 003 Changes the maximum number of entries...

Страница 84: ...ddress book information including the user code 048 Initialize Delivery Addr Book Clears the distribution address book information except the user code 049 Initialize LDAP Addr Book Clears the LDAP ad...

Страница 85: ...o 32 0 1 step This SP does not normally require adjustment This SP is enabled only after the system administrator has set up a group password policy to control access to the address book Compl Opt2 06...

Страница 86: ...ator has set up a group password policy to control access to the address book 091 FTP Auth Port Setting Specifies the FTP port for getting a distribution server address book that is used in the identi...

Страница 87: ...217 is set to 2 Transmit periodically 217 Timing Selects the transmit timing 0 to 2 0 1 step 0 No Transmit 1 Transmit one by one 2 Transmit periodically Installation Date CTL 5849 Displays or prints...

Страница 88: ...off The debug log cannot be captured until this feature is switched on Save to SD Card 006 Specifies the debug log number for saving to an SD card Erase SD Debug 012 Erases SD debug logs in the SD ca...

Страница 89: ...ebugging information to be saved to the destination selected by SP5857 2 SP5858 3 stores one SC specified by number Refer to the chapter Trouble Shooting for a list of SC error codes 001 Engine SC Tur...

Страница 90: ...maining portion of the mail is not received during this prescribed time MDN Response RFC2298 Compliance 0 to 1 1 021 Determines whether RFC2298 compliance is switched on for MDN reply mail 0 No 1 Yes...

Страница 91: ...0 0 Not add 1 Add 005 Adds or does not add the date field to the header of the alert mail 5869 RAM Disk Setting Mail Function GWINIT 0 or 1 0 0 ON 1 OFF 001 Turns on or off the e mail function PDL St...

Страница 92: ...de CTL Enables or disables the automatic reboot function when an SC error occurs 0 or 1 0 0 The machine reboots automatically when the machine issues an SC error and logs the SC error code If the same...

Страница 93: ...o elapse before allowing another application to take control of the display when the application currently controlling the display is not operating because a key has not been pressed 3 to 30 3 1 secon...

Страница 94: ...ot actually work 002 On Board USB 0 or 1 0 1 step 0 Disable 1 Enable SP Print Mode SMC Print 5990 In the SP mode press Copy Window to move to the copy screen select the paper size then press Start Sel...

Страница 95: ...y 001 Latest 002 Latest 1 003 Latest 2 004 Latest 3 005 Latest 4 006 Latest 5 007 Latest 6 008 Latest 7 009 Latest 8 010 Latest 9 CTL Logs the SC codes detected The 10 most recently detected SC Codes...

Страница 96: ...the ADF ARDF that have occurred at a certain timing or at a certain location Original Jam History Display SP7 508 in this chapter 7506 Paper Jam Size Jam Counter Paper Size 7506 5 A4 LEF 7506 6 A5 LE...

Страница 97: ...where CODE is the SP7504 number see above SIZE is the ASAP paper size code in hex TOTAL is the total jam error count SP7003 DATE is the date the jams occurred Size Code Size Code Size Code A4 S 05 A3...

Страница 98: ...0 Latest 9 Sample Display CODE 007 SIZE 05h TOTAL 0000334 DATE Mon Mar 15 11 44 50 2000 Memory Version PN 7801 Displays the part number and version of all ROMs in the machine 7801 255 Memory Version P...

Страница 99: ...A request for the count total failed at power on This error will occur if the device is installed but disconnected 002 Error Staple The request for a staple count failed at power on This error will oc...

Страница 100: ...Prefixes What it means T Total Grand Total Grand total of the items counted for all applications C F P etc C Copy application F Fax application P Print application S Scan application Totals pages jobs...

Страница 101: ...ook Address Book Apl Application B W Black White Bk Black C Cyan ColCr Color Create ColMode Color Mode Comb Combine Comp Compression Deliv Delivery DesApl Designated Application The application Copy F...

Страница 102: ...efers to the document server LSize Large paper Size Mag Magnification MC One color monochrome NRS NRS Remote which allows a service center to monitor machines remotely Remote is used overseas CSS is u...

Страница 103: ...y not available RCG Remote Communication Gate Rez Resolution SC Service Code Error SC code displayed Scn Scan Sim Simplex Simplex printing on 1 side S to Email Scan to E mail SMC SMC report printed wi...

Страница 104: ...scanned with the scanner application but not stored the S count is 4 If both sides of 3 A4 sheets are copied and stored to the document server using the Store File button in the Copy mode window the C...

Страница 105: ...at cannot scan both sides simultaneously the Front side count is the same as the number of pages fed for duplex front side scanning The front side is determined by which side the user loads face up 00...

Страница 106: ...e totals to compare original page size scanning and output printing page size SP 8 441 C Scan PGS Size CTL 0 to 9999999 0 1 8 302 These SPs count by size the total number of pages scanned by the Copy...

Страница 107: ...customer The counter for the application used for storing the pages increments 0 to 9999999 0 1 When the A3 DLT double count function is switched on with SP5104 1 A3 DLT page is counted as 2 When seve...

Страница 108: ...nt back counted as 1 page used for duplex printing Last pages printed only on one side are not counted 0 to 9999999 0 1 T PrtPGS Dup Comb CTL 0 to 9999999 0 1 8 421 These SPs count by binding and comb...

Страница 109: ...Other applications 001 Simplex Duplex 002 Duplex Duplex 003 Book Duplex 004 Simplex Combine 005 Duplex Combine 006 2 2 pages on 1 side 2 Up 007 4 4 pages on 1 side 4 Up 008 6 6 pages on 1 side 6 Up 0...

Страница 110: ...all applications C PrtPGS Ppr Size CTL 0 to 9999999 0 1 8 442 These SPs count by print paper size the number of pages printed by the copy application F PrtPGS Ppr Size CTL 0 to 9999999 0 1 8 443 These...

Страница 111: ...print paper size the number of pages printed by Other applications 001 A3 002 A4 003 A5 004 B4 005 B5 006 DLT 007 LG 008 LT 009 HLT 010 Full Bleed 254 Other Standard 255 Other Custom These counters do...

Страница 112: ...accurately measure the service life of the feed rollers However these counts are based on output timing Blank sheets covers chapter covers slip sheets are also counted During duplex printing pages pri...

Страница 113: ...mode the total number of pages printed by the Copy application F PrtPGS FIN CTL 0 to 9999999 0 1 8 523 These SPs count by finishing mode the total number of pages printed by the Fax application Print...

Страница 114: ...This SP counts the total output broken down by color output regardless of the application used In addition to being displayed in the SMC Report these counters are also displayed in the User Tools dis...

Страница 115: ...e is provided for the Fax application only so SP8631 and SP8633 are the same The counts include error pages If a document is sent to more than one destination with a Group transmission the count is do...

Страница 116: ...y color mode the total number of pages attached to an e mail for the Scan application only 001 B W If Scan to Email is used to send a 10 page document to 5 addresses the count is 10 the pages are sent...

Страница 117: ...hese SPs count by color mode the total number of pages sent to a folder on a PC Scan to PC with the Scan and LS applications S Deliv PGS PC CTL 0 to 9999999 0 1 8 675 These SPs count by color mode the...

Страница 118: ...ion A and location B The counter goes up by 10 not 20 TX PGS Port CTL 0 to 9999999 0 1 8 701 These SPs count the number of pages sent by the physical port used to send them For example if a 3 page ori...

Страница 119: ...8 801 This SP displays the percent of toner remaining for each color This SP allows the user to check the toner supply at any time This precise method of measuring remaining toner supply 1 steps is be...

Страница 120: ...sheets on which the coverage of each color is 31 or higher 8 881 1 BK Page Toner Bottle BCU 0 to 9999999 0 1 8 891 This SP displays the number of sheets output by the scan application 8 891 1 BK Page...

Страница 121: ...h ISO Standards 8 941 1 Operation Time Engine operation time 8 941 2 Standby Time Engine not operating Does not include time spent in Energy Save Low Power or Off modes 8 941 3 Energy Save Time Includ...

Страница 122: ...ominCounter CTL 0 to 9999999 0 1 8 999 Displays the user setting counter for administrator 8 999 1 Total 8 999 3 Copy BW 8 999 7 Printer BW 8 999 10 FaxP BW 8 999 12 A3 DLT 8 999 13 Duplex 8 999 15 Cv...

Страница 123: ...TO PRINTER CONTROLLER The following SP modes are located in the copier SP mode Refer to section 5 1 of the main unit service manual SP No Description Function and Setting 5104 A3 DLT Double Count Spe...

Страница 124: ...Printer Service Mode B867 114 SM NVRAM 7832 Detailed Display of Self Diagnostics Displays the controller self diagnostic result...

Страница 125: ...ics Comments added for your reference This value is stored in NVRAM After a RAM reset the default value factory setting is restored DFU Denotes Design or Factory Use Do not change this value SP1 Mode...

Страница 126: ...M controller data is cleared by SP5 801 xxx for exceptions see Machine Data NVRAM Cleared by Remarks Engine data BICU SP5 998 001 Any data other than controller data GW Controller data Controller SP5...

Страница 127: ...chapter Replacement and Adjustment 9 Refer to the SMC lists and enter any values that differ from the factory settings Double check the values for SP4 901 10 Adjust the standard white level SP4 428 1...

Страница 128: ...can The output given by the menu Big Font is suitable for faxing 3 Press the Execute key Machine The machine status list is output 4 To return to the SP mode press the key 4 5 4 COUNTER EACH PAPER JAM...

Страница 129: ...is caught at the duplex inverter sensor 126 Paper does not reach the duplex entrance sensor 127 Paper is caught at the duplex entrance sensor 128 Paper does not reach the duplex exit sensor 129 Paper...

Страница 130: ...n the right side of the controller box viewed from the back of the machine Before You Begin An SD card is a precision device so always observe the following precautions when handling SD cards Always s...

Страница 131: ...01 255 SD Card Preparation 1 Format an SD card with for example SD Formatter v1 1 1 Create a romdata folder on the card 2 Create the following folders within the romdata folder B245 B268 B276 B277 etc...

Страница 132: ...ller box Slowly push the SD card into the slot so it locks in place 4 Make sure the SD card is locked in place To remove the SD card push it in to unlock the spring lock and then release it so it pops...

Страница 133: ...tall the following firmware simultaneously press the START key The scroll keys can be used to confirm that this firmware has been selected highlighted with a dark background Engine FCU Scanner Printer...

Страница 134: ...main power switch off and on The LCD will display Please wait for about 60 seconds after which it will return to the Program UpDate Menu screen 2 Repeat Steps 1 8 above until all firmware updates are...

Страница 135: ...e SD card E35 Machine model data error Store the correct data in the SD card E36 Module data error Store the correct data in the SD card E40 Engine program error Store the correct data in the SD card...

Страница 136: ...and filename NVRAM serial number NV Here is an example with Serial Number B0700017 NVRAM B0700017 NV 6 In order to prevent an error during the download be sure to mark the SD card that holds the uplo...

Страница 137: ...card from the slot 3 the uppermost one 5 Reassemble the machine In order for the NVRAM data to download successfully the serial number of the file on the SD card must match the serial number of the m...

Страница 138: ...in the controller Main components CPU TOSHIBA TMPR4955BFG 300 PICCOLO GW architecture ASIC It controls all the functions of the controller board Flash ROM 16 MB Flash ROM for the system program SDRAM...

Страница 139: ...Overview SM 129 B867 B867 Printer Scanner Unit Bluetooth interface Wireless LAN interface IEEE1284 interface USB Host...

Страница 140: ...driver the controller stops printing until the user loads the correct paper The Tray Priority setting can be specified using the Paper Size Setting in the user tools User Tools System Settings Paper S...

Страница 141: ...es for the correct size paper to be set in the tray then cancels the print job if the interval expires The interval can be set via Printer Settings in the user tools User Tools Printer Settings System...

Страница 142: ...automatically sends the output to the top tray 1st tray When that tray fills up the machine sends the output to the next tray This feature is called Sequential Stacking If a tray becomes full and the...

Страница 143: ...p does the image processing using the appropriate image processing methods mentioned above Image Data Path 1 Image Store Image Delivery Mode The user can select the following modes from the LCD Delive...

Страница 144: ...rface B867 134 SM 5 4 NETWORK INTERFACE 5 4 1 LED INDICATORS The LEDs are on the optional controller box Description On Off LED1 Green Link status Link success Link failure LED2 Yellow Data rate 100 M...

Страница 145: ...rks without installing or moving wires Most wireless LANs can be integrated into existing wired networks Once installed the network treats wireless nodes like any other physically wired network compon...

Страница 146: ...he default transmission mode is ad hoc mode and the default channel is 11 First set up the machine in ad hoc mode and program the necessary settings even if the machine will be used in the infrastruct...

Страница 147: ...mode and infrastructure mode In such a case to use the device in ad hoc mode use a specified SSID in infrastructure mode and use ASSID in the ad hoc mode WEP Wired Equivalent Privacy WEP is a coding s...

Страница 148: ...y have to change the channel settings To avoid interference with neighboring channels it is recommended that you use a channel separated from another in use by 3 channels For example if there are prob...

Страница 149: ...ucture mode is being used 1 Check if the MAC address is properly set 2 Check the communication status 3 If the communication status is poor bring the machine closer to the access point or check for an...

Страница 150: ...e devices in a Piconet The master device controls the hopping frequency and timing as well as storing the ID codes of the slave devices The master and slave devices can be swapped Once the master devi...

Страница 151: ...nt Profile HCRP are used for the printer products SPP is used in place of the serial port while HCRP is used in place of the parallel port 5 6 3 BLUETOOTH SECURITY FEATURES Public and Private Mode A c...

Страница 152: ...driver is available If the driver is not available a message prompts the user for the driver for immediate installation Hot swapping cables can be connected and disconnected while the computer and ot...

Страница 153: ...and type B connectors for downstream connection to the USB device 5 7 4 PIN ASSIGNMENT The controller has a type B receptacle Pin No Signal Description Wiring Assignment 1 Power Red 2 Data White 3 Dat...

Страница 154: ...ce Related SP Mode USB Settings in the printer engine service mode Data rates can be adjusted to full speed fixed 12 Mbps This switch may be used for troubleshooting if there is a data transfer error...

Страница 155: ...nd Stream an original Ricoh PDL Resolution 600 dpi PCL 6 PCL5e PS3 RPCS 300 dpi PCL6 PCL5e PS3 200 dpi RPCS Resident Fonts PCL 35 Intellifonts 10 True Type fonts PS3 136 fonts 24 Type 2 fonts 112 Type...

Страница 156: ...g Resolution Range Twain Mode 100 to 600 dpi E mail Network Delivery Scanner 100 dpi 200 dpi 300 dpi 400 dpi 600 dpi Scanning Throughput 25 spm for TWAIN 43 spm for Delivery mode A4L ADF mode Interfac...

Страница 157: ...s No The printer drivers for Windows NT 4 0 are only for the Intel x86 platform There is no Windows NT 4 0 printer driver for the PowerPC Alpha or MIPS platforms The PS3 drivers are all genuine AdobeP...

Страница 158: ...Win 95 98 ME NT4 2000 XP Install Manager Win 95 98 ME NT4 2000 XP Install Manager Configuration Win 95 98 ME NT4 2000 XP Printer Utility for Mac This software provides several convenient functions fo...

Страница 159: ...IGURATION 6 3 1 SYSTEM COMPONENTS Item Machine Code Remarks GW Board B843 A Required to install the printer scanner unit Printer Scanner unit B867 C RAM DIMM F Distributed with the printer scanner uni...

Страница 160: ...Machine Configuration B867 150 SM Bluetooth B826 D Embedded RCG M B818 D USB Host B825 E...

Отзывы: