4. Do not put the machine in areas with sudden temperature changes. This includes:
• Areas directly exposed to cool air from air conditioning
• Areas directly exposed to heat from a heating system.
5. Do not put the machine in areas exposed to corrosive gas.
6. Do not install the machine at locations over 2,000 m (6,562 ft.) above sea level.
7. Put the machine on a strong, level base. (Tilting towards any side must be no more than 3 mm.)
8. Do not put the machine in areas with strong vibrations.
Power Requirement
Power Source:
220 to 240V 50/60 Hz 4A or less (Asia/ EU)
120V 60 Hz 6A or less (NA)
Check the machine installation and confirm the following important points:
• Power plug fits tightly in the outlet.
• Power plug is clean and free of dust.
• The machine power plug is not connected to a shared source.
• The machine should be properly grounded.
• The power cord should be free and not wrapped around the leg of a chair or table, or bundled.
Machine Level
Make sure that the machine is located on a flat surface.
Front to back
Within 5 mm (0.2") of level
Right to left
Within 5 mm (0.2") of level
Space Requirements
The machine should be used in a location that meets these minimum space requirements.
2. Installation
36
Содержание Aficio SP 100
Страница 1: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Field Service Manual 26 December 2011...
Страница 2: ......
Страница 75: ...5 Free the harness x1 6 At the front disconnect the fusing unit x4 Basic Procedures 73...
Страница 107: ...Solenoid 105...
Страница 122: ...Ground Plate 1 Note the correct position for the ground plate before re installation 4 Replacement and Adjustments 120...
Страница 124: ...3 Disconnect and remove the board x5 Re installation 4 Replacement and Adjustments 122...
Страница 128: ...8 Remove the center harness bracket 9 Remove the board Re installation 4 Replacement and Adjustments 126...
Страница 135: ...1 Disconnect the speaker harness x1 2 Disconnect and remove the speaker x1 x2 Boards 133...
Страница 139: ...7 Lay the rear cover on a flat surface 8 Disconnect the PSU x6 9 Remove the PSU Boards 137...
Страница 143: ...9 Press the tab release and remove the board x1 AIO Terminals Boards 141...
Страница 149: ...1 Separate both ends of the CIS from the cradles 2 Disconnect the CIS x1 Flatbed Scanner 147...
Страница 156: ...4 Replacement and Adjustments 154...
Страница 173: ...2 Enter the service mode to display the Service Mode screen 1 Fuser SC Detect Utilities 171...
Страница 227: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Appendices 08 March 2012...
Страница 228: ......
Страница 230: ...2...
Страница 244: ...Scan Area TWAIN Driver Flatbed Margin Width mm A Left 0 B Right 0 C Leading 0 D Trailing 0 1 Appendix Specifications 16...