Service Calls
Overview
General
These machines issue an SC (Service Call) when an error occurs. Error codes can be viewed Error
History box of the Service Mode screen in Smart Organizing Monitor.
Pay attention to the following points:
• All SC codes are logged.
• After an error occurs and an SC code is issued, cycle the machine off and on. This usually corrects
the problem.
• Before deciding to replace a PCB (main board, PSU, HVPS) always check the harnesses to make
sure that the problem was not caused by a loose connection.
• Before deciding to replace a motor or sensor, always check around the motor or sensor feeler to
make sure that there is no physical obstruction such as scrap paper or something that has fallen
inside the machine (paper clip, pin, etc.)
Fusing Related SC Codes
A fatal error is issued when a problem occurs inside the fusing unit. Fusing related errors present a fire
hazard so they require special handling.
• Once a fatal error occurs, the machine cannot be used until the problem has been corrected.
Service Calls
199
Содержание Aficio SP 100
Страница 1: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Field Service Manual 26 December 2011...
Страница 2: ......
Страница 75: ...5 Free the harness x1 6 At the front disconnect the fusing unit x4 Basic Procedures 73...
Страница 107: ...Solenoid 105...
Страница 122: ...Ground Plate 1 Note the correct position for the ground plate before re installation 4 Replacement and Adjustments 120...
Страница 124: ...3 Disconnect and remove the board x5 Re installation 4 Replacement and Adjustments 122...
Страница 128: ...8 Remove the center harness bracket 9 Remove the board Re installation 4 Replacement and Adjustments 126...
Страница 135: ...1 Disconnect the speaker harness x1 2 Disconnect and remove the speaker x1 x2 Boards 133...
Страница 139: ...7 Lay the rear cover on a flat surface 8 Disconnect the PSU x6 9 Remove the PSU Boards 137...
Страница 143: ...9 Press the tab release and remove the board x1 AIO Terminals Boards 141...
Страница 149: ...1 Separate both ends of the CIS from the cradles 2 Disconnect the CIS x1 Flatbed Scanner 147...
Страница 156: ...4 Replacement and Adjustments 154...
Страница 173: ...2 Enter the service mode to display the Service Mode screen 1 Fuser SC Detect Utilities 171...
Страница 227: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Appendices 08 March 2012...
Страница 228: ......
Страница 230: ...2...
Страница 244: ...Scan Area TWAIN Driver Flatbed Margin Width mm A Left 0 B Right 0 C Leading 0 D Trailing 0 1 Appendix Specifications 16...