Chapter 2 3 Function of Parts and Circuit
3 Function of Parts and Circuit
Description
Circuit
(1) Interlock Circuit
Opening and closing of the ADF cover and ADF document cover is detected by the micro switch.
This unit does not work for safety unless the ADF cover and ADF document cover are closed. The
unit stops immediately when the ADF cover or ADF document cover are opened during operation.
ADF Cover Switch2
When the ADF Cover is closed : OPEN
ADF Document Cover Switch 2
When the ADF Document Cover is closed : OPEN
White
White
White
CN4-25
-26
2
1
ADF DRIVE PCB UNIT
CN4-1
-2
+24V
DRIVE PCB UNIT
Brown
Blue
1
2
31
32
25
26
When the ADF Cover is opened : CLOSE
When the ADF Document Cover is opened : CLOSE