WARNING!
Equipment which is operated in potentially explosive areas must satisfy the explosion
protection regulations.
Please also refer to the ATEX marking of the pump.
For pumps in accordance with directive 94/9/EC (ATEX) applies:
The pumps are designed for ambient temperatures from -20°C to +40°C.
Magnetic drive pumps
People with a pacemaker are at risk from the strong magnetic field of the magnetic
drive. It may be life-threatening for them to stay at a distance of less than 500 mm to
the pump.
External flushing
The transition pipe is supplied pre-assembled. If other feed lines have been ordered, they are sup-
plied dismantled to facilitate transport. They are then re-assembled using the drawing provided.
HINWEIS!
It is recommended to install a flow monitor in the flushing line. If the minimum flushing
flow is undershot, this sensor then triggers an alarm or the motor is shut off.
Self-priming
The following installation instructions are based on the assumption that a shut-off valve is located
downstream of the pump as a standard feature. There are various different installation configura-
tions.
2.5.2 Installation of pump/unit
The structural work must be prepared in accordance with the dimensions in the installation
drawing. Method of installation: on a grouted base plate and firm foundation
–
Align base plate on the ground foundation.
–
Insert foundation bolts and grout base plate.
–
Do not tighten the foundation bolts uniformly and firmly until the mortar has set.
Safety and installation instructions for Richter pumps
Richter Pumpen /
pumps
Installation > Installation of pump/unit
17