7  Operation 

7.1  Initial commissioning 

Normally, the valves have been tested for leaks with 

air  or  water.  Prior  to  initial  operation  check  cover 

screws. For torques see 

Chapter 1.3

Unless  otherwise  agreed  there  could  be 

residual amounts of water in the flow section 

of the valve.  This could result in a possible 

reaction with the medium. 

To prevent leaks, retighten all connection screws after 

the initial loading of the valve with operating pressure 

and  operating  temperature.  For  tightening  torques, 

see 

Section 1.2

 

 

7.2  Improper operation and their  

consequences 

  The ball valve is an on/off valve and shall not be 

operated in an intermediate position.  

Damage  to  the  seat  rings  or  the  ball/stem  unit  or 

Al

2

O

3

-ball and stem could occur. 

  Avoid  crystallization.  Crystallization  can  cause 

damage to the seat ring and the ball/stem unit or 

Al

2

O

3

-ball  and  stem.  This  can  be  prevented  by 

heating. In extreme cases this may cause blocking. 

  If  the  ball  blocks,  do  not  apply  force  as  the 

ball/stem  may  break  if  the  max.  adm.  torque  is 

exceeded. 

  Increased  wear  occurs  in  operation  with  solids 

contents. 

  Operation  during  cavitation  leads  to  increased 

wear. 

  Non-observance  of  the  pressure-temperature 

diagram can lead to damage.  

  Do not subject the lever to heavy loads; the lever 

or ball valve may be damaged. 

  Do not use a lever extension as otherwise there is 

a risk of damage. 

 

 

7.3  Shutdown  

The  local  regulations  are  to  be  observed  when 

dismantling the valve. 

Prior  to  undoing  the  flange  connection  ensure, 

that the plant is depressurised and emptied. 

Prior to the start of maintenance work, clean 

the valve thoroughly. Medium residue may be 

in  the  valve  even  if  it  has  been  properly 

drained and flushed.  

After  dismantling,  immediately  protect  the  valve 

flanges  against  mechanical  damage  by  using  flange 

caps. See also 

section 6.1

Make  sure  that  a  remote-controlled  actuator 

cannot be switched on by accident. 

 

 

 

 

8  Malfunctions 

  Flange connection ball valve/pipe is leaking 

Retighten the flange screws to a tightening torque 

according to 

section 1.3

. If this does not remedy 

the  leak,  the  recommended  torques  may  be  ex-

ceeded by 10%.  
If  this  also  fails  to  stop  the  leak,  dismantle  and 

inspect the valve. 

  Flange  connection  main  body/body  end  piece  is 

leaking 

Retighten  body  screws.  See  paragraph  "Flange 

connection ball valve/pipe is leaking". 

  Packing  is leaking  

Retighten packing nuts according to the details in 

section 1.3

  Ball valve does not operate 

Is the actuator supplied with power? 
Is  any  directional  control  valve  correctly  connect-

ed?   
Is there foreign matter in the valve? 

  The ball no longer closes completely 

Is the stem deformed? 
Is the coupling worn? 
With a worm gear or actuator, check whether the 

end  stops  can  be  re-adjusted.  The  operating 

manuals  of  the  gear  and  actuator  manufacturers 

contain accurate instructions. 

 

Never  apply  force  to  the  lever  or  use  an 

extension.  

 

1.  Try to get the ball valve working again by moving 

the lever to and from. 

2.  Remove  the  lever  stop  and  try  to  switch  against 

the normal direction of rotation. 

3.  If actuation is not possible with the max. admissi-

ble actuating torque as per 

section 1.4

, dismantle 

ball valve and inspect individual components. 

 

 

Содержание KN-D/F Series

Страница 1: ...operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9520 050 en Revision 18 Edition 11 2018 Series...

Страница 2: ...itial commissioning 11 7 2 Improper operation and their consequences 11 7 3 Shutdown 11 8 Malfunctions 11 9 Maintenance 12 9 1 Dismantling ball valve with ball stem unit 12 9 1 1 Ball valve with lever...

Страница 3: ...walled 5mm body lining KNP D F KNP F with thick walled 5mm body lining KN S F Design stainless steel with lever lockable or hand gear KNP S F Design stainless steel prepared for pneumatic hydraulic or...

Страница 4: ...number Foundry identification Foundry date 1 2 Mounting sleeve for ball stem unit DN200 Nominal size Article No mm inch 200 8 9599 41 8310 Please contact Richter to order the mounting sleeve 1 3 Tigh...

Страница 5: ...DN p in bar 3 6 10 16 max adm mm Nm Nm Nm Nm Nm 15 8 8 8 10 70 20 8 8 8 10 70 25 12 12 12 12 70 40 20 20 20 25 225 50 25 25 25 30 225 80 60 60 65 80 500 100 80 80 90 170 500 150 200 250 350 2200 200...

Страница 6: ...P D F Page 6 9520 050 en Revision 18 TM 9818 Edition 11 2018 1 6 Pressure temperature diagram When used in the minus temperature range the regulations applicable in the country in question must be obs...

Страница 7: ...irective PED for the passage and shut off of fluids The valves are suitable for vapours gases and non boiling liquids of group 1 according to the PED and have a corrosion resistant plastic lining Soli...

Страница 8: ...harges inside the valve However these discharges inside the valve cannot cause ignitions if the valve is completely filled with medium If the valve is not completely filled with medium e g during evac...

Страница 9: ...c surfaces against dirt and mechanical damage Handle the goods being transported with care During transport protect the valve against impacts and collisions Directly after receipt of the goods check t...

Страница 10: ...in the Richter range 6 2 Direction of flow and installation position Installation is independent of the direction of flow Any fitting position can be chosen Otherwise it is marked by a direction arrow...

Страница 11: ...valve Prior to undoing the flange connection ensure that the plant is depressurised and emptied Prior to the start of maintenance work clean the valve thoroughly Medium residue may be in the valve eve...

Страница 12: ...stop into the shaft passage of the main body Remove ball stem unit 201 in closed position Make sure that you do not damage the body lining Only DN200 Carefully slide out the mounting sleeve Remove se...

Страница 13: ...merely be taken apart to remove the stem For sectional drawings see section 10 9 3 1 Ball and seat rings Move ball 200 into the closed position Undo body nuts and bolts Remove body end piece 102 Remov...

Страница 14: ...wers 502 and packing gland follower 503 Tighten packing nuts until there is no gap between packing gland follower 503 and spring gland follower 502 See Section 1 3 and 10 5 Mount bracket 510 with the...

Страница 15: ...550 1 disc DN 150 200 150 554 1 Washer 554 4 Washer DN 25 554 5 Washer DN 80 557 grounding spring washer 577 lever stop 804 Coupling includes 500 Ring Option 952 pressure spring 980 1 round head groo...

Страница 16: ...D F KNP D F Page 16 9520 050 en Revision 18 TM 9818 Edition 11 2018 10 2 Sectional drawings ball valve Ball valve with ball stem unit and lever DN 15 DN 200 150 Holes of the flange and housing screws...

Страница 17: ...Series KN F KNP F KN D F KNP D F Page 17 9520 050 en Revision 18 TM 9818 Edition 11 2018 Ball valve with ball stem unit and worm gear DN 200...

Страница 18: ...NP D F Page 18 9520 050 en Revision 18 TM 9818 Edition 11 2018 10 3 Sectional drawing ball valve and actuator Ball valve with ball stem unit and actuator DN 15 DN 200 Holes of the flange and housing s...

Страница 19: ...KNP F KN D F KNP D F Page 19 9520 050 en Revision 18 TM 9818 Edition 11 2018 10 4 Sectional drawing ball valve with ball stem and lever DN 15 DN 200 150 Holes of the flange and housing screws view dis...

Страница 20: ...P F KN D F KNP D F Page 20 9520 050 en Revision 18 TM 9818 Edition 11 2018 10 5 Sectional drawing ball valve with ball stem and actuator DN 15 DN 200 150 Holes of the flange and housing screws view di...

Страница 21: ...KN F KNP F KN D F KNP D F Page 21 9520 050 en Revision 18 TM 9818 Edition 11 2018 10 6 View and section ball valve with lever View Z Section B B 10 7 Sections ball valve with actuator Section A A Sect...

Страница 22: ...80 100 150 200 1501 L 130 150 160 200 230 310 350 480 457 L4 59 70 88 107 140 175 240 223 5 H 125 158 161 204 222 284 HL 179 259 410 512 5 H1 50 77 80 118 134 184 B 52 69 74 112 130 180 B1 109 138 14...

Страница 23: ...Series KN F KNP F KN D F KNP D F Page 23 9520 050 en Revision 18 TM 9818 Edition 11 2018 Ball valve with ball stem unit and worm gear DN 200...

Страница 24: ...awing ball valve with actuator DN 15 20 25 40 50 80 100 150 200 1502 200 L 130 150 160 200 230 310 350 480 457 457 L4 59 88 107 140 175 240 223 5 228 5 B 52 69 112 130 180 180 238 B1 109 138 240 290 3...

Страница 25: ...r all dimensions in mm DN DIN EN 1092 2 Form B ISO 7005 2 Form B PN 16 Flanges drilled acc to ASME B16 5 Class 150 D k n x d1 k n x d1 mm inch mm mm mm mm mm 15 95 65 4x14 60 5 4x16 20 105 75 4x14 70...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...ation if the safety instructions and the following parameters are observed Device Type A Proof Test Interval 1 year HFT 0 single channel usage SU 129 FIT SD 14 FIT DU 108 FIT DD 36 FIT SFF 62 5 PFDAvg...

Страница 30: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Страница 31: ...hich cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence...

Страница 32: ...materials The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulati...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...ion 17 9520 050 en Richter TM Richter Chemie Technik GmbH IDEX TM IDEX Corporation JOHANNESBURG Tel 011 397 2833 DURBAN Tel 031 579 2593 South Africa 0861 103 103 E mail sales valve co za www valve co...

Отзывы: