Erstellt/
Prepared by
:
CRQ/AL
am/
on
:
27.01.11
Seite/
Page
:
1
Alt: QM-Nr./
QM-No.
:
0905-40-1049_KN/4-00
Genehmigt/
Released by
:
CRQ/AL
am/
on
:
27.01.11
von/
of
:
1
Neu: F722030_KN-00
A Unit of IDEX Corporation
Kempen, 27.01.2011
SIL
Declaration by the Manufacturer
Functional Safety according to IEC 61508
We declare, that the devices
KN, KNR, KNA, KNAR, KNP, KNRP, KNAP, KNARP
are suitable for use in a safety related application, if the safety instructions and the following
parameters are observed:
Device Type:
A
Proof Test Interval:
≤ 1 year
HFT:
0 (single channel usage)
λ
SU
:
129 FIT
λ
SD
:
14 FIT
λ
DU
:
108 FIT
λ
DD
:
36 FIT
SFF:
62,5 %
PFD
Avg
:
4,73 10
-4
(for T
Proof
= 1 year)
MTBF:
398 years
Safety Integrity Level:
SIL 2
The specified values are valid only for the valve. Accessories such as an actuator, solenoid
valves, limit switches etc. are not included.
_________________________________
________________________________
G. Kleining
M. Pohlmann
Leiter Forschung & Entwicklung
Leiter Qualitätsmanagement
Manager Research & Development
Quality Manager