1.2  Tightening torques 

All  screws  greased,  tighten  in  diametrically 
opposite sequence! 

The  tightening  torques  for  pipe  screws  and  body 
screws  mentioned  must  not  be  exceeded.  For  an 
exception,  see 

Section  8

,  Flange  connection  valve  / 

pipe is leaking. 

The following tightening torques are recommended. 

Pipe screws

, flanges to ISO/DIN 

 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[ISO/DIN] 

[Nm] 

[in-lbs] 

25 

4 x M12 

10 

90 

 

Rohrleitungsschrauben 

flanges to ASME Class 150 or flanges ISO/DIN drilled 
to ASME Class 150 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[inch] 

[ASME] 

[Nm] 

[in-lbs] 

25 

1“

 

4 x ½“

 

70 

 
 

Rohrleitungsschrauben 

flanges to ASME Class 300 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[inch] 

[ASME] 

[Nm] 

[in-lbs] 

25 

4 x 

⅝“

 

15 

133 

 
 

Cover screws

 ISO/DIN

 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[inch] 

[ISO/DIN] 

[Nm] 

[in-lbs] 

25 

1“

 

4 x M12 

50 

442 

 
 

Cover screws

 ASME

 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[inch] 

[ASME] 

[Nm] 

[in-lbs] 

25 

1“

 

4 x ½“

 

50 

442 

 
 

 

 

1.3  Screw-in tool for valve seat 

Nominal size 

Article No. 

[mm] 

[inch] 

25 

1“

 

9568-96-1001 

 
 
 
 
 
 

 

1.4  Pressure-temperature diagram 

The  diagram  shows  the  max.  admissible  pressure  / 
temperature loading of the body. 

 

When  used  in  the  minus  temperature  range, 
the  regulations  applicable  in  the  country  in 
question must be observed. 

When  used  in  the  area  of  application  of  ASME  or 
ANSI/ISA,  the low  temperature  of  ASTM  A395  is 
limited to -20°F (-29°C). 

Test pressure p1 

2014/68/EU (PED), AD2000, DIN EN 16668 

 

Back pressure p2 

 

DIN EN ISO 15848-1 certificate valid from -29°C to 180°C 

9500-43-1093.4-00.1

Содержание GUT/F Series

Страница 1: ...erved before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9530 021 en...

Страница 2: ...ion forces 9 6 3 Valve connecting dimensions 9 6 4 Flange caps and gaskets 9 6 5 Direction of flow and installation position 9 6 6 Grounding 9 6 7 Installation 9 7 Operation 10 7 1 Initial commissioni...

Страница 3: ...300 raised face Materials Body material Ductile cast iron EN JS 1049 ASTM A395 Lining material PFA PTFE F On request antistatic PFA L F L highly permeation resistant F P Ultrapure PFA HP F HP Bellows...

Страница 4: ...o ASME Class 300 Flange Nominal size screws Tightening torque mm inch ASME Nm in lbs 25 1 4 x 15 133 Cover screws ISO DIN Flange Nominal size screws Tightening torque mm inch ISO DIN Nm in lbs 25 1 4...

Страница 5: ...ve a corrosion resistant plastic lining Solids can lead to increased wear damage to sealing surfaces or to a reduction in the service life of the valve The overflow valves are set at the works to the...

Страница 6: ...the valve must be completely filled with medium at all times or else a potentially explosive atmosphere must be excluded by superimposing a layer of inert gas b Discharges outside the valve At the poi...

Страница 7: ...a dry vibration free and well ventilated room at as constant a temperature as possible In general a storage period of 10 years should not be exceeded Store the valve in an upright position and secure...

Страница 8: ...s of flow 6 2 Sizing of the outlet line Outlet lines are to be sized so that reliable functioning of the valve is ensured under all expected operating conditions The medium is to be discharged so that...

Страница 9: ...e of metal or enamel can be damaged use PTFE lined seals with a metal inlay These gaskets are available as special accessories in the Richter range 6 5 Direction of flow and installation position Qqq...

Страница 10: ...ssioning When recommissioning the valve make sure that all the appropriate steps as described in Section 6 1 to 6 7 and Section 7 1 are repeated 7 4 Improper operation and their consequences Fig 7 The...

Страница 11: ...re vessels VBG 17 32 and TRD 601 sheet 2 paragraph 3 4 The intervals for regular checks are to be laid down by the customer in line with the operating conditions All repair work is to be performed by...

Страница 12: ...plug and seat Unscrew cap 207 Undo groove nut 509 1 Undo straining screw 581 Do not turn the entire stem 800 There is a risk of the insert sleeve 308 being unscrewed out of the bellows 206 or the fold...

Страница 13: ...ciation of the German Technical Supervi sory Boards All pressure tests should be carried out in compliance with DIN EN 12266 1 or API 527 It is recommended to perform a bubble test with a 5 mm diamete...

Страница 14: ...Series GUT F Page 14 9530 021 en Revision 16 TM 10477 Edition 05 2022 10 2 Sectional drawing...

Страница 15: ...EN 1092 2 type B ISO 7005 2 Type B PN 16 or flanges drilled to ASME B16 5 Class 150 Flanges acc to ASME B16 5 Class 150 or 300 raised face Nominal size EN 558 series 1 ANSI ISA 75 08 01 Class 150 ANSI...

Страница 16: ......

Страница 17: ......

Страница 18: ...om T V S d Industrie Service GmbH Voraussetzung f r die G ltigkeit der Herstellererkl rung ist das Beachten und Einhalten der Betriebsanleitung meet the requirement of the leakage rate La S 10 4 mg s...

Страница 19: ...ls The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to e...

Страница 20: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Страница 21: ...ch cleaning method radioactive3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence of...

Страница 22: ...ai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCedarFalls Info idexcorp com Inte...

Отзывы: