Страница 2: ...TY PRECAUTIONS 3 4 GENERAL SPECIFICATIONS 5 5 INDICATIONS FOR USE 5 6 CONTRAINDICATIONS 5 7 SYSTEM AND COMPONENTS 6 8 OPERATING INSTRUCTIONS 7 9 MAINTENANCE AND STORAGE 10 10 DEVICE STORAGE 11 11 TROU...
Страница 3: ...trainer has a pump and dual lower extremity garments with air cells The patient puts the garments on the pump inflates the air cells to compress muscles promote venous blood return and to help preven...
Страница 4: ...e 104 F 40 C On back of device and instruction manual On back of device On back of device On back of device On garments On back of device The Pump is Class II Protection The garments is Type BF Applie...
Страница 5: ...d sunburned bruised or broken skin or with skin conditions such as skin cancer dermatitis eczema or psoriasis in or around treat ment sites Should changes in skin appearance occur such as blisters red...
Страница 6: ...will void the warranty DO NOT hold the unit or attachments by the tubing DO NOT wrap the tubing around the garments as it could cause damage to the tubes not covered by the warranty DANGER WARNINGS On...
Страница 7: ...JL 201 AC125V 10A 2 pole without earthling contact NISPT 1 2 0 824mm Thermoplastic Urethane 0 30 mins 20 200mm Hg 4 70s REF DVTREX LE L DVTREX LE U Length inch cm 44 110 44 110 Width inch cm 14 35 16...
Страница 8: ...CONTROLS DISPLAY 7 SYSTEM AND COMPONENTS Pneumatic Compression Pump Garments for Leg Use Position Setting Mode Setting Power On Off Timer Setting Pressure Setting Start Pause 6...
Страница 9: ...ents on each leg and pull up the zipper NOTE Lower Extremity Garments inflate deflate simultaneously and tubing is already attached to the garments Must put both garments on to work properly 3 Connect...
Страница 10: ...eutic Mode A or B 6 Set the timer by choosing between 10 20 or 30 mins When the timer is done the device will automatically stop and go into standby mode NOTE Recommended treatment time is 30 mins per...
Страница 11: ...The max pressure of the pump core is 230 to 260mmHg The max flow of the pump core is 16L 18L min 8 Position Setting Press corresponding number shown below based on how many chambers you want to inflat...
Страница 12: ...amp not wet cloth using mild soap and water solution once per month as needed Garment Cleaning Disinfecting Instructions 1 Disconnect garment from device Open garment to expose all sides either by sep...
Страница 13: ...e and or loud noises Move to a more stable and even surface 10 DEVICE STORAGE The device should be stored in a clean dry area between 59 to 77 F 15 to 25 C However short term exposure to temperatures...
Страница 14: ...discharge ESD IEC 61000 4 2 8kV contact 2kV 4kV 8kV 15kV air 8kV contact 2kV 4kV 8kV 15kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative...
Страница 15: ...this device is used exceeds the applicable RF compliance level above this device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary...
Страница 16: ...between portable and mobile RF communications equipment transmitters and the device as recommended below according to the maximum output power of the communications equipment For transmitters rated at...
Страница 17: ...sumer or during transport to the retailer Accessories which are subject to normal wear and tear Liability for direct or indirect consequential losses caused by the unit is excluded even if the damage...