35
,
), the machine will move accordingly.
Note:
The movement will be carried out according to the current speed mode
and the set distance, it is not affect by the „grid‟, so it will not stop on grid point. To change
the distance value, triple press “
” re-enter the „Distance‟ value setting.
5.3.3
Manual testing input and output
Under the initial boot interface, pressing “
", the screen will displays as follow,
1) IptCheck(Manual test input ports)
From left to right are respectively represent: X HOME, Y HOME, Z HOME, tool setting,
servo driver alarm, hard limit, emergency stop and foot switch. The port definitions will be
a little different in individual custom system.
Manual trigger the corresponding signal, the corresponding signal
changed from L
to H means the signal is in normal status
. If not, it is abnormal. User should check the
corresponding switch, wiring and 50 pins cable. The screen will displays as follow.
To trigger X1 (X axis HOME switch), the corresponding letter changed, means X1
signal is normal, X2 to X8 detecting are in the same way.
Note
: Do not confuse with “Voltage setup”.
I/O Detection
IptCheck
OptCheck
Volt Lvl
KeyCheck