26
27
TROUBLE SHOOTING GUIDE
SYMPTOM
PROBABLE CAUSE
SUGGESTED ACTION
NO DISPLAY
AT THE LCD
PANEL
NO POWER.
Check power is on at circuit breaker, disconnect switch, and
check wiring connections.
Check fuse (refer to fuse specs in the
installation instructions) in the junction box.
LOOSE CONNECTION(S).
Check connections in the J/box (near operator)
and control panel; check that the ribbon cable to LCD display
is firmly connected at both ends.
VOLTAGE DROP IN WIRING
BETWEEN OPERATOR
JUNCTION BOX TO
CONTROL PANEL.
Check voltage between te24 and COM,
if no power or Dyna-Hoist voltage is less than 23V, check
wiring between Junction box (near operator)
and control panel.
LCD PANEL ASSEMBLY.
If 24Vdc is detected and ribbon cable is connected then
replacement of LCD panel assembly may be required.
CONTROL PANEL CIRCUIT
BOARD.
Disc24V wire (from the J/box) in the control
panel, check voltage between disconnected wire and
COM terminal, if voltage is 24Vdc then replacement of
control panel circuit board may be required.
DOOR STOPS AT
RANDOM (DOES
NOT RECOGNIZE
LIMITS) POSITION.
ENCODER WORN,
IMPROPERLY INSTALLED
OR HAS MOVED.
Check encoder for wear, re-position if necessary. It is
critical that the set collar on the shaft be set at 3" from
the end. Run limits setup, replace encoder if problem
persist.
DOOR CONSTANTLY
STOPS SHORT OF
CLOSE POSITION
MOTOR POSITION SETTING
MAY BE INCORRECT.
Check Motor Position from SETUP menu, (Operator
position LH or RH as viewed from Interior) and change if
necessary. Reset Limits. Note: All operators are factory
setup for LH mounting.
DOOR REVERSES
BEFORE REACHING
CLOSE POSITION
OR AS SOON AS
THE CLOSE BUTTON
IS RELEASED
PHOTO-EYE/REFLECTOR/
THRU-BEAM SENSOR
MISALIGNED/
OBSTRUCTED/MISWIRED.
Clean, re-align and/or clear obstruction in front of the
sensors/reflector. Re-check wiring as shown in Diagram
1 on Page 13.
FORCE MONITORING IS
TOO SENSITIVE
Adjust the Closing Force setting in the Advanced
Menu. 1 is most sensitive, and 20 is least sensitive.
THIRD PARTY REVERSING
DEVICES MALFUNCTIONING
.
Disconnect third party reversing devices, install jumper
between reversing input terminal 3 and +24 and test
again. Reconnect reversing devices one at a time to
isolate the defected device, (refer to page 11-17 In the
installation manual).
Содержание DYNA-HOIST DC Series
Страница 7: ...7 TORQUE ARM POSITION IN RELATION TO OPERATOR ...
Страница 13: ...13 WIRING DIAGRAMS ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 26: ...26 DYNA HOIST OPERATOR COMPONENTS ...
Страница 31: ...31 NOTES ...