background image

 

 

 

 
 
 

Содержание INVERTEK L series

Страница 1: ......

Страница 2: ...unctions 4 G Rear View Main Functions 5 H Left View Main Functions 5 I Pre installation Information 6 J Electrical Requirements 6 K Installation Requirements 6 L Connection and Testing 8 M Operation 1...

Страница 3: ...Features include Capable of driving inductive loads i e electric Tools and appliance Compact light weight rugged and vehicle rated 83 90 efficient Standard specially designed AC and DC line filters D...

Страница 4: ...in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connections between components of the fuel s...

Страница 5: ...used properly E Introduction The power inverter series are the member of the most advanced line of mobile AC power systems available To get the most out of the power inverter it must be installed and...

Страница 6: ...OVP Over voltage protection OTP Over Temperature Protection UVP Under voltage protection OLP Over Load Protection POWER Power ON RUN STANDBY Indicates current operating condition of the inverter 3 AC...

Страница 7: ...24V 48V power source is positive is negative WARNING Reverse polarity connection will blow internal fuse and may damage inverter permanently H Side View Main Functions The communication port of Remote...

Страница 8: ...s 1 Where to install The power inverter should be installed in a location that meets the following requirements Dry Do not allow water to drip or splash on the inverter free of salt or moisture laden...

Страница 9: ...mage Report any concerns immediately to your supplier Mount the inverter to a suitable surface paying close attention to the mounting requirements previously mentioned in this manual 2 AC Wiring Impor...

Страница 10: ...input terminals on the inverter Your cables should be as short as possible ideally less than 10 feet 3 meters and large enough to handle the required current in accordance with the electrical codes or...

Страница 11: ...Check the indicators on the front panel of the inverter The voltage bar graph indicate depending on the voltage of the battery If it does not check your battery and the connections to the inverter The...

Страница 12: ...0 Watts up to 3000 Watts 2 Over voltage indicator The over voltage indicator indicates that the power inverter has shut itself down because its input voltage higher than the detect voltage 12V 24V 48V...

Страница 13: ...t located to the right of the two lamps below the power point Turning this control fully clockwise will override the standby circuit and keep the inverter ON all the time this could be used if you hav...

Страница 14: ...hat the true power rating of your appliance including power factor is less than the output rating of your inverter Inverter shuts down when trying to start a load A sudden surge in load such as a moto...

Страница 15: ...foot This minimizes radiated interference from the cables 2 Troubleshooting guide Problem and Symptoms Possible Cause Solution Low output voltage 110V 100 120 VAC 220V 200 240 VAC Using average readi...

Страница 16: ...ur inverter operating properly You should clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input ter...

Страница 17: ...ications TYPE A N American B U K C Australia D Europe E Universal INPUT 12 VDC 24 VDC 48 VDC 0150 WATT 0300 WATT 0600 WATT 1000 WATT 1500 WATT 3000 WATT OUTPUT 1 110 V 2 220 V DAI 0150L 1 2 1 A DC TO...