![Rice Lake Synergy 680HE Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/rice-lake/synergy-680he/synergy-680he_technical-manual_1453958067.webp)
Maintenance
© Rice Lake Weighing Systems
●
All Rights Reserved
61
10.4 Battery Replacement
The battery life varies depending on use. It is recommended to replace the battery every three years, or sooner, if left powered
off for extended periods of time, to prevent data loss in the event of a power failure.
Use Revolution (
) to store a copy of the 680HE configuration
on a PC before attempting battery replacement. The 680HE configuration can be restored from the PC if data is lost.
Risk of explosion if battery is replaced with an incorrect type. Dispose of used batteries according to federal,
state and local regulations.
Use anti-static protection for grounding and to protect components from electrostatic discharge (ESD) when
working inside the 680HE enclosure. Procedures requiring work inside the 680HE must be performed by
qualified service personnel only.
Figure 10-1. Non-Conductive Screw Driver Placement
To replace the battery, use the following procedure:
1. Disconnect power to the indicator.
2. Release the two latches and carefully swing open the front door of the enclosure.
3. Place the tip of a non-conductive flat head screw driver between negative contact and battery.
4. Twist screw driver to release battery from holder.
5. Press new replacement battery straight into the battery holder with the positive side up. See
for replacement battery details.
10.5 Board Replacement
Use anti-static protection for grounding and to protect components from electrostatic discharge (ESD) when
working inside the 680HE enclosure. Procedures requiring work inside the 680HE must be performed by
qualified service personnel only.
To replace a 680HE board, use the following procedure:
1. Disconnect power to the indicator.
2. Release the two latches and carefully swing open the front door of the enclosure.
3. Label connections for re-installation to board.
4. Disconnect all connections from the board.
5. Remove the four corner screws securing the board.
6. Slightly lift up on the board and disconnect the overlay ribbon from the J26 connector on the reverse side of the board.
7. Attach the overlay ribbon to the new board by pressing the end up against the J26 connector while it is still closed.
Open the J26 connector and then close it once the end of the overlay ribbon has seated itself inside the connector.
8. Place the new replacement board into the enclosure and secure with the four previously removed screws.
9. Reconnect all connections to the board. See
for details on the board connectors.
Always verify indicator has been returned back to a safe state with the proper installation of all connections and