40
SCT-1100 Weight Transmitter
Parameter
Settings
Description
Selection of active channel;
1 to 4 in scales with non dependent channels functioning mode (
/
NOTE: The parameter is not displayed if
is set in the
. parameter or
in the event of a single channel application,
.
= disable
yes = enable
Enable or disable the 50Hz filter
Metrologic parameters
Select and set the type and degree of filtering
-
–
Filter for simple weighing
-
– Filter at 100 Hz
-
–
Filter for high resolution
-
–
Filter for crane scale
-
–
Filter at 50 Hz
-
–
Filter at 200 Hz
–
Filter for serial conversion/transmission at 400Hz
–
Customizable filter for manufacturer use
NOTE: The
and
filters cannot be used in the
2, 3 and
4 channel functioning modes.
Automatic acquisition of the gross zero at startup (up to ± 10% of capacity)
–
Enabled on scale 1
–
Disabled
–
Executed cyclically on all the present scales. This parameter is not visible if
there is only one scale
NOTE: If auto zero is enabled,
displays and a value between 1 and 50 as
a percentage of the capacity of the auto zero must be set.
Zero capacity – This menu allows to set (0 to 50%) of capacity that can be zeroed by
pressing
; Entering 0% disables the
key
Zero tracking – This menu allows setting the zero tracking (compensation parameter of
the scale’s thermal drift); the set value corresponds to the number of divisions reset in 1
second
–
± half division
–
± one fourth of a division
–
± one division
–
± two divisions
–
tracking disabled
Divisions by stability – Enter the number of divisions by which the instrument detects the
weight stability; the higher the number of divisions the less sensitivity and stability is
more easily detected; Settable values are 0 (weight always stable) to 99
9,75001-9,84999
default: 9,80655
Gravity acceleration – select the acceleration value of calibration and of use of the
instrument; Manual entry of the g value: the gravitational acceleration value may be
manually entered; The minimum decimal value is 9.75001m/s
2
; any decimal number
that is not between 9.75001 and 9.84999 m/s
2
(inclusive), is incorrect
Scale calibration – See
Zero calibration – See
Table 4-8. Config Menu Parameters and Settings
Содержание SCT-1100
Страница 1: ...SCT 1100 Advanced Series Weight Transmitter Technical Manual PN 185658 Rev A October 31 2017...
Страница 86: ...82 SCT 1100 Weight Transmitter...
Страница 87: ......