Setup Mode
37
4.2.4
Analog Output
Figure 4-4. Analog Output Menu
Table 4-6. Analog Output Parameters
Parameter
Settings
Description
See
for configuring the analog output;
This parameter is not displayed if
is selected;
– selects the slot to be used with the analog output:
•
•
Select the active channel 1-4 in the scale with non dependent channels mode (
/
); The
parameter is not displayed
is set in the
parameter or in a single channel application,
Sets the capacity of the scale;
Enter the capacity set on the primary instrument (000000 to 800000);
The parameter displays only in the secondary mode
Sets the analog operating mode
If the instrument is a primary:
•
–
analog output disabled.
•
–
analog output on the gross weight
•
–
analog output on the net weight
If the instrument is a secondary:
•
–
analog output disabled
•
–
analog output enabled
Maximum value – Sets the maximum value of the analog output (00000 to 65535)
Scale zero value – Sets the analog output value when the scale is at zero weight (00000 to 65535)
Minimum value – Sets the minimum value of the analog output (00000 to 65535)
Sign – This parameter displays only if the selected operating mode is net weight; In the secondary mode,
functioning on negative weight is not managed
•
=
Functioning with positive weight.
•
= Functioning with negative weight.
6(WX3
DQRXW
W\SH
PRGH
DRPDK
&KDQ
$R=(U
$R0LQ
6L*Q
$RQR
$RQHW
$R*UR
xxxxxx
xxxxxx
xxxxxx
3R6LW
QH*DW
Содержание SCT-1100
Страница 1: ...SCT 1100 Advanced Series Weight Transmitter Technical Manual PN 185658 Rev A October 31 2017...
Страница 86: ...82 SCT 1100 Weight Transmitter...
Страница 87: ......