Service information

17

4.4.3

Replacement Parts List and Accessories

Stainless Steel 
Junction Box

Standard Plastic 
Junction Box

5

4

7

15

14

1

6

3

2

8

9

10

11

12

13

Table 4-4. Replacement Parts List

Item No.

Part No.

Description

1

21172
21173

Junction box, standard plastic - 4 channel, signal trim (HP/HP-H - H/HC models)
Junction box, NEMA 4X - 4 channel, signal trim (SS and HE models)

2

26087

Strain relief flex fitting (HP/HP-H - H/HC models)

3

15611

Cable, 6-wire, deck to indicator

4

26320

Junction box tray (HP/HP-H - H/HC models)

5

14876

Junction box tray screw (HP/HP - H/HC models)

6

14908

Junction box tray screw (SS and HE models)

7

15398
15377

Rubber grommet, load cell cable (HP/HP-H/HC models)
Rubber grommet, deck to indicator cable (HP/HP-H-H/HC models)

8

15658

Cable tie mount, 1” square

9

15631

Cable ties, 3”

10

15071
15075
40337

Load cell screw, (HP/HC models)
Load cell screw, (SS and HE models)
Load cell screw, (HP-H model)

11

18756
39021
39022

Foot assembly (HP/HC, SS and HE models)
Foot assembly (20K HP-H model)
Foot assembly (30K HP-H model)

12

Consult factory for 
replacement parts

Load cells

13

18777
18778
40387
40388

Mounting plate, HP and HC models, set of two plates (optional)
Mounting plate, SS and HE models, set of two plates (optional)
Mounting plate, 20K HP-H models, set of two plates (optional)
Mounting plate, 30K HP-H models, set of two plates (optional)

14

15051

Overload stops (HC Canadian legal-for-trade models only)

15

15410

Bubble level (HC Canadian legal-for-trade models only)

Содержание RoughDeck ALTRALITE

Страница 1: ...RoughDeck Low Profile Floor Scale SS HE HP HP H HC and ALTRALITE Installation Manual utilizes economical junction box 16960 Rev B...

Страница 2: ......

Страница 3: ...4 2 Periodic Maintenance 13 4 3 Load Cell Replacement 13 4 3 1 Load Cell Wiring to the Junction Box 15 4 4 Replacement Parts List and Accessories 16 4 4 1 Pit Frames 16 4 4 2 Access Ramps 16 4 4 3 Rep...

Страница 4: ...ii RoughDeck Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Страница 5: ...losed in conduit through the main channels and held down with replaceable cable ties near each corner eliminating the possibility of cable damage in portable applications Also useful for portable appl...

Страница 6: ...r death Contact any Rice Lake Weighing Systems dealer for replacement manuals Proper care is your responsibility Before attempting to operate this unit make sure every individual who operates or works...

Страница 7: ...xternal mounted NTEP certified model with hermetically sealed load cells and NEMA 4X J box for hostile environments 1 3 Operating Requirements Electrical Grounding For systems where the scale is conne...

Страница 8: ...e where overweight loads can maneuver easily without crossing the platform Avoid areas where damage could occur from side impacts of wheels or forklift tines Avoid areas where falling objects could ca...

Страница 9: ...curely attached through the nuts welded to the bottom side of the top plate Lifting from the bottom of the plate could cause nuts to break loose and the scale to fall Figure 2 1 Proper Lifting Techniq...

Страница 10: ...s to secure the scale feet 3 50 2K 20K models 4 50 30K 562 DIA 2K 10K models 812 DIA 20K 30K MOUNTING PLATE SCALE DECK FOOT Figure 2 2 Mounting Plate Installation 2 5 Electrical Interface to the Indic...

Страница 11: ...scale for servicing or cleaning LOAD CELL CABLE STEEL COVER FLOOR SCREW LOAD CELL CABLE STEEL COVER Figure 2 4 Cable Protection Strain Relief Flex Fitting Figure 2 5 Standard Junction Box Note In wash...

Страница 12: ...loor sweepings or material spills may accumulate in the pit and interfere with scale operation periodically clean the pit All RoughDeck models have threaded holes for eye bolts so the scale can be eas...

Страница 13: ...sary Access ramps can only be attached to the scale on one of the two scale sides that are perpendicular to the longitudinal axis of the load cells For example the scale shown in Figure 2 8 could have...

Страница 14: ...ll must be matched by adjusting the signals with potentiometers at the junction box a process known as trimming All assembled RoughDeck scales are delivered with the junction box corner trimmed Corner...

Страница 15: ...of the test weight used 3 3 Calibration Procedure Refer to the indicator manual to determine correct calibration procedures It is recommended that the scale be exercised before calibration to be certa...

Страница 16: ...brated Calibrate according to indicator manual and Section 3 3 on page 11 Load cells faulty Test and replace load cells if necessary Feet touching deck underside Adjust feet downward to provide cleara...

Страница 17: ...ELL 2 CELL 1 1 4 2 3 Note Figure 4 2 shows both the scale and the junction box as viewed from the bottom To verify correct load cell junction box terminal matching see the numbers on the terminals ins...

Страница 18: ...n trimming and calibration is necessary after load cell replacement Follow instructions in Section 3 2 and Section 3 3 on page 11 4 3 1 Load Cell Wiring to the Junction Box 1 4 2 3 Figure 4 4 Corner N...

Страница 19: ...764 39599 39612 5 x 6 1 53 x 1 83 18769 18770 39600 5 x 7 1 53 x 2 13 18771 18772 39601 39614 6 x 6 1 83 x 1 83 39602 39615 6 x 8 1 83 x 2 44 39604 7 x 9 2 13 x 2 74 39605 7 x 10 2 13 x 3 05 39606 396...

Страница 20: ...ength x Ramp Height Access Ramp for Model ft x ft x inch m x m x mm HP H 20K HP H 30K 4 x 4 x 4 1 22 x 1 22 x 102 39585 5 x 4 x 4 1 52 x 1 22 x 102 39586 6 x 4 x 4 1 83 x 1 22 x 102 39587 7 x 4 x 4 2...

Страница 21: ...bber grommet load cell cable HP HP H HC models Rubber grommet deck to indicator cable HP HP H H HC models 8 15658 Cable tie mount 1 square 9 15631 Cable ties 3 10 15071 15075 40337 Load cell screw HP...

Страница 22: ...that the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged no...

Страница 23: ...9171 Immediate Emergency Service For immediate assistance call toll free 1 800 472 6703 Canadian and Mexican customers please call 1 800 321 6703 If you are calling after standard business hours and h...

Страница 24: ...20 RoughDeck Low Profile Floor Scale...

Страница 25: ......

Страница 26: ...8 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Weighi...

Отзывы: