Communications
©
Rice Lake Weighing Systems
●
All Rights Reserved
21
Samples of Escape Protocol
Examples of what is sent to the computer from the scale.
Figure 5-1. Escape Protocol Examples
Examples of diagnosing battery request and responses.
Figure 5-2. Diagnose Battery Examples
5.2.2 Maintenance Protocol
Maintenance protocol commands are listed below.
Command
Definition
R
Reboot
V
Firmware ID + development version
W
Current weight
A
Current AD
Z
Zero the scale
F
Show flash values (used for the first flash process)
L
USB On/Off (not available on USB communication
Table 5-5. Maintenance Protocol Commands
Escape Protocol Example 1
Escape Protocol Example 2
<ESC>R <ESC>E
Reading
(request)
EOP
<SCALE>
<PC>
EOP
Unit of Measure
= Metric
<ESC> R <ESC> W0210.9 <ESC> Nm <ESC> E
Reading
(Command)
Weight = 0210.9
<SCALE> <PC>
direction of communication
Diagnose Battery Request
Battery OK Response
Battery Low Response
<ESC> ABAT <ESC> E
Diagnose battery
EOP
<SCALE> <PC>
direction of communication
<ESC> ZE4U <ESC> E
Battery is okay
(no errors)
EOP
<SCALE> <PC>
direction of communication
<ESC> ZE4L <ESC> E
Battery is very low
(Unstable)
EOP