7.10 Setpoint Commands
Command
Description
Values
BATCHNG
Batching mode
OFF
(default), AUTO, MANUAL
SP.KIND#
n
Setpoint kind
OFF
(default), GROSS, NET, -GROSS, -NET, ACCUM, POSREL, NEGREL,
PCTREL, PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG, COZ, INMOTON,
INRANGE, BATCHPR, TIMER, CONCUR, TOD, ALWAYS, NEVER
SP.VALUE#
n
Setpoint value
0.0–9999999.0,
0.0
(default)
SP.TRIP#
n
Trip
HIGHER
(default), LOWER, INBAND, OUTBAND
SP.BANDVAL#
n
Band value
0.0–9999999.0,
0.0
(default)
SP.HYSTER#
n
Hysteresis
0.0–9999999.0,
0.0
(default)
SP.PREACT#
n
Preact type
OFF
(default), ON, LEARN
SP.PREVAL#
n
Preact value
0.0–9999999.0,
0.0
(default)
SP.PREADJ#
n
Preact adjustment percentage
0.0–100.0,
0.5
(default)
SP.PRESTAB#
n
Preact learn stability (in tenths of a second) 0–65535,
0
(default)
SP.PCOUNT#
n
Preact learn interval
1–65535,
1
(default)
SP.BATCH#
n
Batch step enable
OFF
(default), ON
SP.CLRACCM#
n
Clear accumulator enable
OFF
(default), ON
SP.CLRTARE#
n
Clear tare enable
OFF
(default), ON
SP.PSHACCM#
n
Push accumulate
OFF
(default), ON, ONQUIET
SP.PSHPRINT#
n
Push print
OFF
(default), ON, WAITSS
SP.PSHTARE#
n
Push tare
OFF
(default), ON
SP.ALARM#
n
Alarm enable
OFF
(default), ON
SP.ALIAS#
n
Setpoint name
Up to 8 alphanumeric characters,
SETPT
(default)
SP.ACCESS#
n
Setpoint access
OFF,
ON
(default), HIDE
SP.DSLOT#
n
Digital output slot
NONE
(default), 0
SP.DIGOUT#
n
Digital output
1–4,
1
(default)
SP.SENSE#
n
Digital output sense
NORMAL
(default), INVERT
SP.BRANCH#
n
Branch destination (0 = do not branch)
0–8,
0
(default)
SP.RELNUM#
n
Relative setpoint number
1–8,
1
(default)
SP.START#
n
Starting setpoint
1–8,
1
(default)
SP.END#
n
Ending setpoint
1–8,
1
(default)
SP.TIME#
n
Trip time
hhmm,
0000
(default)
SP.DURATION#
n
Trip duration
hhmmss,
000000
(default)
SP.ENABLE#
n
Setpoint enable
OFF,
ON
(default)
For setpoint commands ending with
#n
, n is the setpoint number (1-8)
Table 7-10. Setpoints Commands