4.6 Total
For the accumulation of multiple weighments, the total function uses the displayed load, so gross and net readings can be
added into the same total.
There are four modes of totalizing: manual and three auto modes. The manual mode requires the
TOTAL
key be pressed with
the weight on the scale. The weight is added to the previously accumulated value. This assures that a weight on the scale is
only added to the total once.
Both the manual and three auto total modes require that the weight on the scale return below 0.5% (relative to full scale) of
GROSS ZERO
or
NET ZERO
before the next weighment can be added. Applied weight must be ≥1% of full scale above
GROSS
ZERO
or
NET ZERO
before it can be totaled.
Manual Total
The
USER
key under the Manual Total mode functions in this manner:
• Weight is greater than 1% of capacity and has not been totaled – Pushing the
USER
key will add the current weight to
the TOTAL weight. The ACK LED’s blink to indicate the weight was accepted. The
TOTAL
annunciator lights and the
Total weight displays for five seconds and then the number of samples displays for two seconds.
• Current Weight has been totaled – Pushing the
USER
key displays the Total weight for five seconds (View Total) without
changing the Total value. The
TOTAL
annunciator will light during the TOTAL weight display. After five seconds of Total
Weight display, the number of samples displays for two seconds.
• Weight is less than 1% of capacity – The
USER
key functions as View Total only and functions as View Total until the 1%
threshold is exceeded to allow the next addition to the total value.
Auto Total
The
USER
key under the
AUTO TOTAL
mode functions as Auto Total On / Auto Total Off.
The Auto Mode has three variations which are programmed in the
Setup
menu:
•
– AutoLoad
ensures any settled load above the
Rise above
threshold will be automatically totaled. The scale
must fall below the
Drop below
threshold before the next total is allowed.
•
– AutoLast
mode takes the last settled weight to auto total with. The total occurs only once the scale goes
below the threshold. This allows the load to be adjusted without a total occurring. Once the load is removed, the scale
uses the last settled reading for total.
•
– AutoHigh
uses the highest settled reading. This is useful for loads that can’t be removed all at once.
Total Mode will not function while the scale is in motion, make sure
is on. If the system fails to achieve stable
readings, increase the filter setting or increase the size of the scale division (d) in the Init Cal procedure.
Set Total Mode
1. If the unit is turned off, press and hold
then press
If the unit is on, press
and
simultaneously.
displays.
2. Using the
, scroll to
.
3. Press
. The currently saved total mode displays.
4. Press
to scroll through the selections.
5. With selection displayed, press
to select.
displays.
6. Press
to save and exit to weighing mode or press
to continue to another
Setup
menu item.
Note