4.5 Setpoints
The MSI-4260 IS supports three setpoints. Common uses of set points are for warnings or process control. It comes standard
with LED outputs for a triggered set point.
Figure 4-1. Setpoint LEDs
Contact Rice Lake Weighing Systems for other setpoint output options, which are displayed below.
To set the setpoint:
1. Press and hold
and
.
displays.
2. Press
to scroll to the desired setpoint (
).
3. Press
. The current
mode displays.
4. Press
to scroll to the setpoint mode desired.
5. Press
. The current
weight type displays.
6. Press
to scroll to the desired weight type.
7. Press
. The current setpoint weight value displays.
8. Press
. The first digit blinks.
9. Press
to scroll to the desired number.
10. Press
. The second digit blinks.
11. Repeat steps 8-10 until the desired value displays.
To enter a decimal point, press
while the digit is blinking. To correct a digit, press
to step back.
12. Press
. The value stops blinking and the next
Setup
menu item displays.
13. Repeat steps 2-12 to set all the setpoints to be used.
14. Press
to exit setup and store the settings.
Press
at any time to cancel the procedure.
Setpoint
Description
Setpoint Mode
Indicates the setpoint will trigger when the weight exceeds a set value
Indicates the setpoint will trigger when the weight is less than a set value
Setpoint Weight Type
responds to net or gross weight
responds to gross weight regardless of the display
responds to the totaled weight
responds to the total count (number of samples)
LFcnt
responds to the number of times the weight has exceeded 25% of capacity
Table 4-2. Available Setpoint Settings
Setpoint 1 is Blue
Setpoint 2 is Green
Setpoint 3 is Red