2.2.3 Battery Replacement
1. Turn the MSI-4260 IS off.
2. Hold the battery cover and release the latches.
3. Slowly lower the cover while holding the battery in place.
4. Remove the battery by pulling straight back.
5. Charge the spent battery in a safe area.
6. Install a fully charged battery by plugging it in to the exposed battery jacks.
7. Close the battery cover.
8. Reset the latches. Make sure the latches are completely latched and the cover is firmly in place.
Figure 2-2. Remove Battery
Periodically, inspect the battery latches for fit. Adjust the screw latch by rotating the catch on its threads to
maintain a tight seat on the battery O-ring.
The 12 V Sealed Lead Acid battery can be a dangerous falling hazard. When opening the battery hatch, be sure
to hold the battery to prevent it from falling. These batteries contain lead and should be recycled when it has
reached its end of life.
Only an Intrinsically Safe Battery (PN 167777), can be used with the MSI-4260 IS. This battery is incompatible
with non-Intrinsically Safe MSI product. The intrinsically safe battery pack can be removed in the protected area,
but must be charged in a safe environment.
2.3 Servicing
The entire scale must be shipped back to Rice Lake Weighing Systems for repair. Please contact a local dealer or Rice Lake
Weighing Systems to obtain a return material authorization (RMA). There are no user serviceable parts within the MSI-4260 IS
.
All repairs are to be performed by qualified service personnel only. Removing the warranty and liability label compromises the
FM rating.