Rice Lake Master BS211 Скачать руководство пользователя страница 12

Appendix

7

4.0

Appendix

4.1

Installation and Wiring

4.1.1

MOUNTING

weighframe

Drawings

WBF-S0000

BS211-M0200

Junction Box

Drawings

JBB-M0200

JBL-ATEX-M0200

Speed pickup

Drawings

SPU260-M0200

4.1.2

WIRING DIAGRAMS

Drawing

BS211-E0299

4.2

Declarations

CE-Declaration

Model

BS211

Serial number

0

ATEX-Declaration

Zone

21

22

Category

II2D  IP65  T70

o

C

II3D  IP65  T70

o

C

Temperature

T

A

= -10

o

C / + 40

o

C

4.3

Specifications

Standard

Material

Weighframe

Steel St.37 or Stainless Steel SS304 / 316

Rollers

Aluminum, Steel St.37 or SS304 / 316

Weight

Dependent on the belt width

Load Cells

1 or 2 pieces model B3G-9363 (SS / IP65/67)

Capacity 50 to 2500 kg (each)

Power supply 5-15 VDC (stabilized from electronics)

Signal nominal 2 mV/V at 100% load

Junction Box

Model JBB (PC / IP65)

Speed Pick-up

Standard model SPU5020

(Alu / IP66)

Optional model SPU5826

(SS / IP66)

Optional model SPU2160N

(Alu / IP64)

ATEX cat. II2D or II3D

Load Cells

1 or 2 pieces model BM11-SHB (SS / IP66/68 / ATEX II2D T70°C)

Capacity 50 to 200 kg (each)

or:

1 or 2 pieces model BM8H-ACB (SS / IP66/68 / ATEX II2D T70°C)

Capacity 500 to 2000 kg (each)

Junction box

Model JBL-ATEX (ABS / IP65 / ATEX II2D IP6X T80°C)

Speed Pick-up

Std. model SPU5020

(Alu / IP66 / ATEX II3D IP6X T=120°C)

Opt. model SPU5826

(SS / IP66 / ATEX II3D IP6X T=120°C)

Opt. model SPU7030HSR

(SS / IP66 / ATEX II2D T70°C)

Содержание Master BS211

Страница 1: ...Austin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and measurement products since 1931 ...

Страница 2: ...BS211 Belt Scale Installation Manual 165455 ...

Страница 3: ......

Страница 4: ...ance 6 3 1 1 Periodical maintenance 6 3 2 List Parameters for Belt Scale 6 4 0 Appendix 7 4 1 Installation and Wiring 7 4 1 1 MOUNTING 7 4 1 2 WIRING DIAGRAMS 7 4 2 Declarations 7 4 3 Specifications 7 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www ricelake com training or obtained by calling 715 234 9171 and asking fo...

Страница 5: ...ii BS211 Belt Scale Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars ...

Страница 6: ...in damage to equipment or corruption to and loss of data General Safety WARNING Do not operate or work on this equipment unless you have read and understand the instructions and warnings in this manual Failure to follow the instructions or heed the warnings could result in injury or death Contact any Rice Lake Weighing Systems dealer for replacement manuals Proper care is your responsibility Failu...

Страница 7: ... an integration function in the electronics These electronics totalize calculate the mass flow displays these and transfers it through outputs or any other way of communication to a control system or network For the operation we refer to the manual of the electronics installed 1 3 Selection Criteria After choosing the belt scale model BS211 the dimensions are determined The capacity of the load ce...

Страница 8: ...tions in the conveyor should be allowed to carry over to the weighframe If needed these must be filtered The belt must be of a good quality and the weld must not influence the weighing A good fit consists of more than one part and welds the weight per meter must be constant over the whole length The belt must not track out of the center and no steering idler must be placed near the weighing area T...

Страница 9: ...ction box near the weighframe not further than 0 5 meter from it The cable glands must point downwards 2 2 Electrical Installation The wiring and connections between weighframe speed pickup and the electronics are shown in the applicable scheme see Section 4 1 on page 7 The load cell is provided with a fixed cable do not alter the length An additional junction box with screw terminals is provided ...

Страница 10: ...If necessary the load cell will be adjusted mechanically 2 3 2 Electronics Setup Refer to the manual of the electronics installed 2 3 3 Calibration Perform a test with material Let the installation run and totalize for a duration of at least 5 minutes Collect the material during this period and compare the totalized value with a measurement on a static scale If necessary adjust the calibration par...

Страница 11: ...eriodical maintenance Check to ensure there is not a build up of debris on the belt Inspect the weighframe for damaged areas and repair immediately to prevent rusting The method of application and the specifications of the painting may be customer specific and therefore have to be requested Regularly perform an Auto Zero and a weight check with certified test weights to determine if the belt scale...

Страница 12: ...on the belt width Load Cells 1 or 2 pieces model B3G 9363 SS IP65 67 Capacity 50 to 2500 kg each Power supply 5 15 VDC stabilized from electronics Signal nominal 2 mV V at 100 load Junction Box Model JBB PC IP65 Speed Pick up Standard model SPU5020 Alu IP66 Optional model SPU5826 SS IP66 Optional model SPU2160N Alu IP64 ATEX cat II2D or II3D Load Cells 1 or 2 pieces model BM11 SHB SS IP66 68 ATEX ...

Страница 13: ...8 BS211 Belt Scale NOTES ...

Страница 14: ......

Страница 15: ...54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 88 2349171 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Weighing Systems 09 2014 PN 165455 ...

Отзывы: