Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
21
3.7.1 Command Format (7-Segment)
4”, 6” and Stop/Go remotes
|<AA><CC>|<Data>!
Where:
| = Pipe character (Ox7C)
AA = Two byte address, ASCII digits (0–31)
CC = Two byte command, ASCII characters
| = Pipe character (Ox7C)
Data = Data depending on command
! = Exclamation point character (0x21)
Example Commands and Responses
Get time and date:
|00GT!
Get the version number: example return “2.05”
|00GV!
Set the temperature adjustment
|00TP#!
Where # is -5
–
+5 (example |00TP-1!, |00TP+3!, |00TP5) default is 0
Dump the configuration parameters (test purposes only):
|00GDC!
Command
Description
DM
<Data> is the six character or less message
Example: |00DM|HELLO!
GT
Get time and date; Information gathered is sent back to the indicator, allowing both the remote display and indicator to match;
This is not displayed on the remote display
Example: |00GT!
ST
Set time and date
Example: |ST08:00:00 2003-01-31!
NOTE: Two spaces are required between time and date entries.
DI
Read digital input levels (returns “0”=LL, “1”=LH, “2”=HL, “3”=HH) (
DO
Set digital output levels (“DO0”=LL, “DO1”=LH, “DO2”=HL, “DO3”=HH) (
GR
Get relay state; data=relay (ASCII character “0” - “1”) (
SR
Set relay state; data=relay (ASCII character “0” - “1”) and state (“ON = gnd, “OFF = +5 V) (
GV
Get the version number
DC
Dump configuration parameters (for testing purposes only)
TP
Temperature adjustment; Allows ±5% degree adjustment
Time and date is sent from the remote display depending on the current remote display time and date format;
Time and date are sent to the remote display in ISO format:
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back
Table 3-9. Command Format