Configuration
29
Level 3 submenus
GROSSSP
NETSP
–RELSP
VALUE
PSHTARE
PSHPRNT
TRIP
BANDVAL
HYSTER
ALARM
PSHACCM
PREACT
PREVAL
BATCH
ACCESS
NAME
DIGOUT
RELNUM
Configure GROSSSP, NETSP, and –RELSP setpoints. See Level 4 parameter
descriptions.
PAUSE
DELAY
WAITSS
PSHTARE
PSHPRNT
PSHACCM
ACCESS
DIGOUT
NAME
VALUE
Configure PAUSE, DELAY, and WAITSS setpoints. See Level 4 parameter
descriptions.
TIMER
CONCUR
VALUE
START
END
ACCESS
DIGOUT
Configure TIMER and CONCUR setpoints. See Level 4 parameter descriptions.
NAME1–NAME16
name
Specify up to 16 setpoint names. Names can be assigned to GROSSSP, NETSP,
–RELSP, DELAY, and WAITSS setpoint types.
Level 4 submenus
VALUE
number
GROSSSP, NETSP, –RELSP setpoint types: Specifies the target weight value.
DELAY, TIMER, and CONCUR setpoint types: Specifies, in 0.1-second intervals, a
time value in the range 0–65535.
PSHTARE
OFF
ON
GROSSSP, NETSP, –RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify
ON to perform an acquire tare operation when the setpoint is satisfied.
PSHPRNT
OFF
ON
WAITSS
GROSSSP, NETSP, –RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify
ON to perform a print operation when the setpoint is satisfied; specify WAITSS to
wait for standstill after setpoint is satisfied before printing.
PSHACCM
OFF
ON
ONQUIET
GROSSSP, NETSP, –RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify
ON to update the accumulator and perform a print operation when the setpoint is
satisfied. Specify ONQUIET to update the accumulator without printing.
TRIP
HIGHER
LOWER
INBAND
OUTBAND
GROSSSP, NETSP, and –RELSP setpoint types: Specifies whether the setpoint is
tripped when the weight is higher or lower than the setpoint value, within a band
established around the value, or outside of that band.
In a batch sequence with TRIP=HIGHER, the associated digital output is active until
the setpoint value is reached or exceeded; with TRIP=LOWER, the output is active
until the weight goes below the setpoint value.
SETPNTS Menu
Parameter
Choices
Description
Table 3-7. Setpoint Menu Parameters