Maintenance
© Rice Lake Weighing Systems
●
All Rights Reserved
33
8.0
Maintenance
8.1 Troubleshooting
Problem
Possible Cause
Solution
Display is blank when
Power
key is
pressed
Discharged battery
Recharge, allow at least four hours charge
Defective battery
Replace
Corroded battery or battery contacts
Clean contacts
Defective switch or circuit board
Requires authorized service
Display does not function properly, front
panel keys do not function normally, or
scale will not turn off
Improperly updated software.
Reinstall software
Faulty circuit board
Requires authorized service
Loose connectors
Requires authorized service
Scale does not respond to weight changes Out of calibration
Calibrate
Faulty load cell
Replace
Load cell connector
Check connector and wires
Display over ranges below 100% capacity Tared weight is added to load to determine overload
point
Return to
Gross Weight
mode
Zero requires adjustment
Rezero the scale
Too much weight has been zeroed
Rezero the scale
Display Drifts
AZM
(Auto0) is turned off
Turn
AZM
on
Rapid temperature changes such as moving the scale
from indoors to outdoors
Wait until the scale temperature has stabilized
Displayed weight shows large error
Scale not zeroed before load is lifted
Zero the scale with no load attached
lb/kg units causing confusion
Select proper units
Requires recalibration
Recalibrate
Display reading not stable
Excessive vibration in crane system
Increase filtering or increase
d
in cal
Excessive side loading
Improve load train symmetry
Load cell faulty
Check LC connections
Display toggles between Error and Load
Weight exceeds capacity
Reduce weight immediately
Faulty load cell or wiring
Check LC and LC wiring
Display toggles between Error and A2DLo A/D is saturated negative
Check LC and LC wiring
Display toggles between Error and buttn
A key is stuck or is being held down
Check switches for damage
Ensure that a remote is not transmitting continuously
Optional RF remote does not work
Units not mated
See
for additional network
setup information
Lo Batt
is blinking
Battery is low
Recharge battery
Unit turns on, then immediately off
Battery is low
Recharge battery
Weight will not zero
System not stable
Wait for motion annunciator to turn off
Increase filtering for more stability
Zero out of range
LFT units have limited zero range; Reduce the weight
or use tare instead
Weight will not tare or total
System is not stable
Wait for motion annunciator to turn off, or if in a
mechanically noisy crane, increase the filtering or
reduce the size of the scale increment
d
; The motion
window can also be increased. Contact RLWS if there
is a problem getting the MSI-3460 to zero, tare, or total
due to stability issues
Setpoint lights blink
Setpoint is enabled and the trigger point has been
reached
Disable setpoints if they are not needed
Manual total does not work
A function key is not set to Total
Set up Func1 or Func2 for Total
Weight must be stable
Increase filtering for more stability
Auto total does not work
Weight must be stable
Wait for the motion light to go out, or increase filtering
for more stability
Weight thresholds not reached
Weight thresholds must exceed 1% of capacity for
autototal to work; Then it must drop below 0.5% of
capacity for additional weighments to register
Table 8-1. Troubleshooting