![Rice Lake Challenger 3 MSI-3460 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/rice-lake/challenger-3-msi-3460/challenger-3-msi-3460_technical-manual_1454124012.webp)
MSI-3460 Challenger 3
8
Visit our website
3.4 Battery Charger
The charger is a three-stage float charger that can be left on the battery indefinitely. It has a dual color LED to indicate the
charging state:
RED – Fast charge mode
GREEN – Charged or float charge
Charge the Battery
1. Remove the battery from the scale.
2. Plug the battery charger into an AC power receptacle. The input voltage is universal from 115/230 VAC, 50/60 Hz.
If the power input plug doesn’t match, contact Rice Lake Weighing Systems for information on international plugs.
3. Slide the battery charger connector plate over the top of the battery until the battery terminals mate with the charger
connectors, as viewed through the two observation holes.
4. Six to eight hours is required to recharge a fully discharged battery. Partially discharged batteries finish the charge
faster.
Figure 3-3. Battery Charger
To obtain maximum service life from the batteries, the manufacturer suggests recharging after each 20 hours of use.
Continuous deep discharging reduces the maximum battery life cycle estimated at 2000 cycles.
A second battery is recommended to enable continuous scale use. Keep one on the charger while the other is in