Configuration
9
3.0
Configuration
3.1
User Settings
When navigating the user settings menu, press
to scroll through the parameters and options. Press
to
select.
Table 3-1. User Settings
Parameter
Options
Definition
30 sec, 1 min, 3 min, 5 min, No off
Auto Off Time Setting
On, Auto, Off
Backlight Setting
nci, 8213, ECr, EH-SCP, SMA
Protocol (model dependent)
1200,2400,4800,9600,19200,38400, 57600
Baud rate
7 even, 7 odd, 7 none, 8 none
Parity
1,2
Stop bits
On, Off
Tare
RAM, ROM, DIV-A, DIV-O
Diagnostics
Done (exit)
Note
After selecting all parameter settings, move to the
parameter and press
to confirm and save settings.
3.2
Service Menu
The service menu provides all configuration settings and access to perform calibrations.
To navigate the service setting menu, press
to scroll through the parameters and settings; press
to select.
Press
to return to the previous parameter.
To enter into the service menu:
1. Remove the scale platform.
2. Remove the sealing screws.
Sealing screws
main PCB cover
Battery cover
Die-cast base
enclosure
Load
bridge
Primary
operator
display
Figure 3-1. Remove Sealing Screws
3. Press
to power on the scale.
—