Rice Lake 880 Performance Series Скачать руководство пользователя страница 5

880 Relay Option Card Installation

© Rice Lake Weighing Systems

 

 All Rights Reserved

5

Connection Pin Assignments

The indicator automatically recognizes installed option cards when the unit is powered on. No hardware-specific 

configuration is required to identify the newly-installed card to the system.

Figure 7. Relay Option Card Board

Specifications

4 SPST:

Normally Open Dry Contact Relays

250 VAC @ 3A

30 VDC @ 3A

Relay Protection:

The use of external fusing to limit current is recommended. Relay COM-NO are transient 

protected to 400V @ 600W

Relay Contacts:

Displayed as Slot 1, Bit 1-4 in the setpoint configuration menu

J1 Pin

Signal

1

K1

Common

2

K1

Normally Open

3

K2

Common

4

K2

Normally Open

5

K3 

Common

6

K3

Normally Open

7

K4

Common

8

K4

Normally Open

Table 2.  Pin Assignments

Note

K4

L

ED1

LED4

J1

K2

K1

LED7

LED

8

LED2

K3

LED

3

LED6

S1

J3

LED5

J6

LED

9

J4

Relay

1

2

3

4

5

6

7

8

Отзывы: