482-AG Livestock Digital Weight Indicator
6
Visit our website
1.7.1 Numeric Keypad - Editing Procedure for Numeric Values (482 Plus Only)
Figure 1-6. Numeric Keypad for the 482-AG
With the numeric keypad, numbers can be edited using the keypad in addition to the arrow method.
1. When editing numeric values, insert the required value using the numeric keypad.
i. Press
to set the currently selected digit to 0
ii. Press
to enter a decimal point
2. Press
to save the value entered and return to the level above.
When editing fractional numeric values, the decimal point must be positioned in accordance with the primary units
formatting, otherwise the keyed number may be rejected by the software.
1.8 Indicator Operations
Basic operations for the 482-AG are summarized below.
1.8.1 Zero Scale
1. Remove all weight from the scale and wait for the
annunciator to light.
2. Press
. The
annunciator lights to indicate the scale is zeroed.
1.8.2 Toggle Units
Press
to toggle between primary and secondary units. The current unit annunciator is displayed.
Units cannot be changed once a group weighment has been started.
1.8.3 Print Ticket
The print key sends the group data to the serial port. This key will also reprint a group ticket for the current group data on the
indicator. For more information on print formatting, see
1. Wait for
annunciator to display.
2. Press
to send data to the serial port.
If the
key is pressed when the
is not displayed, unless the scale stabilizes withing three seconds,
the print command is ignored.
1.8.4 Shrink Factor
The shrink factor limits are 0.0% to 99.0%. The default is 0.0%. In the weigh mode, enter the shrink factor on the numeric
keypad and press
. The entered shrink factor is applied to every weighment until the shrink factor is changed or the
indicator is reset. A shrink factor, however, can be entered at any time, but only the last shrink factor prior to pressing
will be applied to all of the groups making up the load. The shrink factor is not displayed when weighing, however, the shrink
factor value and results are printed on the load total ticket only. The entered shrink factor is stored and will survive power
cycles.
Note
Note
Note
Note