background image

NOVO-GLOSS

™ 

Flex 60° 

 

 

 

 

 

Thank you for purchasing this Rhopoint product. 
Please read these instructions carefully before operating this product and retain them for 
future reference. 
The images shown in this manual are for illustrative purposes only. 

English 

Operating Instructions 

Содержание NOVO-GLOSS Flex 60

Страница 1: ...chasing this Rhopoint product Please read these instructions carefully before operating this product and retain them for future reference The images shown in this manual are for illustrative purposes...

Страница 2: ...reserve the right to change information included in this document without prior notice Copyright 2016 Rhopoint Instruments Ltd All Rights Reserved Rhopoint Novo Gloss and Rhopoint are registered trad...

Страница 3: ...ch Data 13 User Defined Batch Names 13 Setup Screen 14 Data Batch Screen 15 Calibration Screen 16 Measurement Screen 17 Pass Fail Setup Screen 18 Control Screen 19 Instrument Setup Screen 20 Maintenan...

Страница 4: ...bient temperature Ensure that the instrument is not exposed to moisture chemicals or to any corrosive vapours Do not interfere or place any objects inside the measuring aperture as damage to the measu...

Страница 5: ...lossmeter High and low gloss calibration tiles including certificate Cleaning cloth for calibration tile BAM traceable instrument certificate USB mains charger with four selectable mains input connect...

Страница 6: ...with the unit This will fully charge the unit when connected to the unit s USB input 6 using the USB cable provided in approximately 3 hours Do not use the instrument to take measurements whilst conne...

Страница 7: ...all instrument functions are available however do not operate the instrument whilst it is connected via USB and or charging Functional Overview The instrument is controlled by pressing the relevant to...

Страница 8: ...ents can be made by simply pressing any of the measurement buttons With the pass fail feature enabled the Novo Gloss Flex 60 will compare each measurement range to user defined tolerances If the gloss...

Страница 9: ...in the statistics screen will access the graph screen providing a graphical representation of the statistics data Measurements can be taken whilst in this screen and the graph will be updated after e...

Страница 10: ...re calibrated individually GU 0 100GU GUh 0 12GU 1 Select GU calibration tile 2 Attach tile to measurement head for best performance place on a flat surface 3 Navigate to Menu Setup Calibration Menu 4...

Страница 11: ...select Confirm once completed 6 Select GUh calibration tile 7 Attach tile to measurement head for best performance place on a flat surface 8 Navigate to Menu Setup Calibration Menu 9 Ensure Calibrate...

Страница 12: ...ed range or to detect contamination on the tile in case of error the following message will be displayed 12 In case of error check the correct tile is selected step 1 or step 6 13 If the correct tile...

Страница 13: ...no of measurements and statistics data updated to previous values Start New Batch Start new batch of readings batch name is incremented by 1 Clear Current Batch Delete entire batch of measurements fo...

Страница 14: ...reached a new batch will start Viewing Batch Data To access the stored batch information connect the instrument to a PC using the USB data cable supplied A new device name NG FLEX 60 can be viewed an...

Страница 15: ...ata options See Data Batch Menu Screen Calibration Menu Calibration options See Calibration Menu Screen Measurement Menu Geometry setup See Measurement Menu Screen Control Menu Bluetooth setup See Con...

Страница 16: ...1 250 by pressing the Left and Right buttons to select the relevant digit and the Up and Down buttons to increase decrease the value Pressing the Enter button saves the batch size If Batch names have...

Страница 17: ...the Calibration screen are Calibrate instrument Performs an instant calibration of the instrument a dialogue box being displayed upon completion to either Cancel or Confirm Calibrate to Set to GU a tr...

Страница 18: ...for monitoring surfaces for changes over a period of time Pressing the Enter button selects the required measurement frequency of either 2 5 or 10 seconds When auto measure mode is activated a dialogu...

Страница 19: ...the right navigation button allows the user to edit pass fail criteria Once the Pass Fail feature is enabled any measurement which falls between the max and min values will be considered a pass and i...

Страница 20: ...ing the Up and Down buttons navigates through the options pressing the Enter button selects that option Settings in the Control screen are ID Measurement definition header SOF EOF Start End of file ma...

Страница 21: ...ensity to either 20 40 60 80 or 100 brightness Power Off Set instrument to automatically power off after either 30 60 90 or 120 seconds of inactivity or DISABLE this feature Power Switch Set On Off bu...

Страница 22: ...igurable settings available in this menu Pressing the Enter button returns the display to the home screen About Screen The About screen is for information only It provides information relating to the...

Страница 23: ...ration data can be instantly accessed by many PC applications including Excel Word WordPad OpenOffice or SPC packages Pairing Procedure 1 Switch on the instrument 2 The Bluetooth icon must be visible...

Страница 24: ...Printers screen Click Add a device 6 Windows will now search for available Bluetooth devices double click on the icon that corresponds to the instrument 7 Click Enter the device s pairing code in the...

Страница 25: ...xtend auto power off refer to instructions detailed in the Instrument Setup Screen section 9 The Novo Gloss Flex 60 is now installed on your PC and ready for connection to the Bluetooth Data Widget It...

Страница 26: ...eystrokes that are automatically input into any open PC program 1 Install the BT Data Widget software BTdatawidget exe found on the DVD supplied with the instrument 2 Check Bluetooth is switched on an...

Страница 27: ...drop down box to see discovered instruments 7 Select the instrument required 8 Click the green tick to connect the instrument The transmitter icon now appears on the Novo Gloss Flex 60 All readings wi...

Страница 28: ...ATION 60 geometry GU GUh Measurement range 0 125 GU 0 125 GUh Resolution 0 1 GU 0 1 GUh 0 01 GU Repeatability 0 2 GU 0 5 GUh 0 05 GU Reproducibility 0 5 GU 2 0 GU 0 2 GU Standards ISO 2813 ISO 7668 AS...

Страница 29: ...n board trend analysis Power Rechargeable lithium ion Up to 17 hours operation Up to 20 000 readings per charge Memory 8MB 2 000 readings User definable alphanumeric batching Data Transfer Bluetooth P...

Отзывы: