COMMISSIONING 

50 

IN-SERIES BOOSTER 

Refer  to  the  Owner’s  Guide  and  Installation  Instructions  supplied  with  the  in-series  water  heater  for  the 
commissioning procedure of the in-series water heater. 
 
If a continuous flow gas water heater has been installed as an in-series gas booster to the solar water heater, 
then to complete the installation, it is necessary to check the gas supply pressure at the inlet to the in-series 
gas booster, and also the minimum test point pressure and the maximum test point pressure of the in-series 
gas booster. Refer to 

“Gas Inlet Pressure” and to “Burner Gas Pressure” in the Owner’s Guide and Installation 

Instructions supplied with the in-series gas booster. 
 

PRESET OUTLET TEMPERATURE 
Note:

 AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in 

potable  water.  If  this  water  heater  is  installed  with  an  in-series  continuous  flow  gas  booster,  then  this 
requirement of AS 3498 can be satisfied provided the booster is energised, its preset outlet temperature setting 
is 70°C or higher and a remote temperature controller or an EZiSET kit is not used. 
 
If  this  water  heater  is  installed  with  an  in-series  storage  booster,  then  this  requirement  of  AS  3498  can  be 
satisfied provided the storage booster is energised and its thermostat setting is 60°C or higher. 
 
It will be necessary to check and if required to adjust the preset outlet temperature setting of the continuous 
flow water heater or the thermostat setting of a storage water heater when it is installed as an in-series booster 
to a solar water heater or if it is an existing water heater and a solar water heater is then installed. 
 
Refer to the Owner’s Guide and Installation Instructions supplied with the in-series continuous flow gas booster 
for the procedure to check and adjust the preset outlet temperature if required. 
 
Refer to the Owner’s Guide and Installation Instructions supplied  with the in-series storage booster for the 
procedure to check and adjust the thermostat setting if required. 
 

Note:

  Consideration  must be  given  to the  delivery  temperature  to  any  ablution  and  public  areas  such  as  a 

bathroom, ensuite or public amenities. Refer to 

“Hot Water Delivery”

 on page 26 and to the schematics of 

“Two 

Temperature Zones Using A Temperature Li

miting Device”

 on page 27. 

 

BLEEDING THE SOLAR COLLECTOR(S) 

Upon  completion  of  the  installation,  if  the  service  3-
way  valve  was  not  opened  during  the  tank  filling 
procedure,  then  it  is  necessary  to purge  the  air  from 
the collector circuit. 
 
To purge air from the collector circuit: 

 

Ensure the water heater is full of water and all of 
the hot taps are turned off. 

 

Using  a  pair  of  pliers  or  other  appropriate  tool, 
open the service 3-way valve fitted at the solar hot 
water  inlet  (from  collector)  of  the  solar  storage 
tank (see diagram). 

 Warning:

 Stand well aside of the service valve 

drain  pipe  discharge  point  and  exercise  care  to 
avoid any splashing of water, as water or in some 
circumstances  steam  discharged  from  the  solar 
collector(s) may be of a very high temperature. 

 

The mains pressure will force water to flow from the tank and through the pipe work, forcing air from the 
collector  circuit  through  the  service  valve.  This  is  evidenced  by  spurting  of  water  from  the  drain  line 
connected to the service valve. 

Note:

 Allow  water to flow from the drain line for  a few minutes before closing the service valve. Water 

already in the solar hot pipe will drain out prior to air in the top of the collector circuit being purged by the 
mains pressure water rising in the solar cold pipe. 

 

Close the service valve when water runs freely under mains pressure from the drain line. 

 

Service 3-Way Valve 

SERVICE 3 WAY VALVE

Solar Pumped Open Circuit

Содержание 511161

Страница 1: ...er Owner s Guide and Installation Instructions Solar 511161 Storage Tank WARNING Plumber Be Aware Use copper pipe ONLY Plastic pipe MUST NOT be used It is a requirement of a solar water heater install...

Страница 2: ...cluding concealed in cavities and roof spaces or where it may be in contact with a metal roof may lead to freeze damage The system has NO WARRANTY for freeze damage if the solar hot and solar cold pip...

Страница 3: ...quirements 12 Water Supplies 15 Save A Service Call 18 Installation System 22 Installation Solar Storage Tank 25 Installation Solar Control Unit 34 Installation Solar Collector s 37 Connections Plumbi...

Страница 4: ...Terms of the Rheem Warranty on page 58 This solar water heater is designed to be installed with a Rheem continuous flow 874 series 20 or 26 litre in series gas booster either mounted onto the storage...

Страница 5: ...temperature operation during that day The desired water temperature in the solar storage tank is to be between 60 C to 70 C If the solar control unit has entered Over temperature operation during the...

Страница 6: ...booster will boost the water temperature automatically to its preset outlet temperature setting or to the temperature setting of another type of in series booster water heater The factory preset outle...

Страница 7: ...d Service Agent to arrange for an inspection The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these i...

Страница 8: ...and solar collector s from freezing It is essential the electrical circuit to the solar control unit is continually turned on if there is a risk of freezing The Rheem warranty does not cover damage c...

Страница 9: ...urs 4 x red Hot sensor in collector open circuit no green remains off Power outage or call for service 5 x red Cold sensor short circuit 6 x red Cold sensor open circuit If the power supply to the sol...

Страница 10: ...ater has been switched off Switch on the electrical supply to the solar control unit at the power outlet The power outlet must be switched on for the solar control unit to operate and solar gain to be...

Страница 11: ...E WATER HEATER The water heater is suitable for most public water supplies however some water chemistries may have detrimental effects on the water heater the solar collectors components and fittings...

Страница 12: ...ly installed Rheem in series continuous flow gas booster it is recommended minor maintenance be performed every six months on the gas booster by the dwelling occupant Another type of in series booster...

Страница 13: ...heating period This occurs as the water is heated and expands by approximately 1 50 of its volume Continuous leakage of water from the valve and its drain line may indicate a problem with the water h...

Страница 14: ...glass with water and a soft brush when the solar collector s is cool such as early in the morning In extremely dusty areas extra attention may need to be given to keeping the collector glass clean Ha...

Страница 15: ...er of the water heater is only covered by the Rheem warranty when the total dissolved solids TDS content in the water is less than 2500 mg L and when the correct colour coded anode is used If an incor...

Страница 16: ...ted by an unusual spurting of the water from the tap Once the water runs freely any hydrogen in the system will have been released SATURATION INDEX The saturation index is used as a measure of the wat...

Страница 17: ...1 0 solar collector copper sheathed heating unit Saturation Index SI 0 4 if an expansion control valve is not fitted water heater cylinder temperature pressure relief valve Saturation Index SI 0 8 sol...

Страница 18: ...f the glass is dirty the effectiveness of the solar collector s will be greatly reduced Have the trees trimmed or the solar collector s relocated if the obstruction is permanent or clean the collector...

Страница 19: ...ere has been heavy hot water usage A Rheem continuous flow solar gas booster will operate if the solar heated water temperature is lower than 58 C Fan Continues To Run After Water Heater Operation Sto...

Страница 20: ...ay take up to ten 10 minutes If the red LED continues to emit a rapid pulse for longer than ten 10 minutes switch off the electrical supply at the power outlet to the solar control unit for a few seco...

Страница 21: ...on page 18 Is there a leaking hot water pipe dripping hot water tap etc Even a small leak will waste a surprising quantity of hot water and energy Replace faulty tap washers and have a plumber rectify...

Страница 22: ...e requirements for safety whilst manual lifting working at heights and on roofs Installers must be competently trained in Height Hazard Assessment Working at Height Procedures Assessment Use Wearing o...

Страница 23: ...ng the system model number exactly as it is shown in the VEET Product Register published by the Essential Services Commission in Victoria see www veet vic gov au This documentation may be in the form...

Страница 24: ...ater heater provided The in series booster water heater is thermostatically controlled and suitable to be used as an in series booster water heater for a solar water heater The operating pressures of...

Страница 25: ...must stand vertically upright on a stable base as acceptable to local authorities The base of the water heater is made of corrosion resistant material and it may be placed directly in contact with the...

Страница 26: ...hot water outlets in any ablution and public areas such as a bathroom ensuite or public amenities to reduce the risk of scalding The installing plumber may have a legal obligation to ensure the instal...

Страница 27: ...d water line to the solar water heater and the cold water line to a temperature limiting device branches off before this valve or from another cold water line in the premises then a pressure limiting...

Страница 28: ...mperature setting must be set to 70 C or higher If the in series water heater is a storage water heater to meet this requirement of AS 3498 its thermostat must always be set to at least 60 C Water sho...

Страница 29: ...r for the Rheem warranty to apply to the water heater cylinder refer to Water Supplies on page 15 and the Anode Selection chart on page 15 The black anode is typically fitted as standard Total Dissolv...

Страница 30: ...olar control unit prior to mounting the in series gas booster Refer to Installation Solar Control Unit on page 34 The service 3 way valve assembly must be fitted prior to mounting the in series gas bo...

Страница 31: ...AND TECHNICAL DATA storage tank only remote boost storage tank with integrated boost Model Capacity Tank Mass kg without booster Tank Mass kg with booster Empty Full Empty Full 511 161 165 litres 62 2...

Страница 32: ...INSTALLATION SOLAR STORAGE TANK 32 TYPICAL INSTALLATION INTEGRATED BOOST OUTDOOR LOCATION Typical Installation Solar Loline 160 Open Circuit With Integrated Gas Boost...

Страница 33: ...L INSTALLATION REMOTE BOOST OUTDOOR LOCATION TYPICAL INSTALLATION REMOTE BOOST INDOOR LOCATION Typical Installation Solar Loline 160 Open Circuit With Remote Gas Boost Typical Installation Solar Lolin...

Страница 34: ...e 3 way solar assembly consisting of 1 x service valve 3 way solar 2 x nut compression 2 x olive compression copper 1 331658 Union body R 3 4 M x DN15 olive 1 331655 Nut compression DN15 1 331656 Oliv...

Страница 35: ...threaded joints Conetite or O ring fittings do not require a thread sealant Note The solar control unit automatically controls the flow rate through the collector circuit This is achieved via the hot...

Страница 36: ...adjacent to the union 2 at the solar cold outlet connection 10 Insulate the lower end of the preformed pipe 3 cold sensor and union 2 with an 80 mm long x 35 mm ID piece of insulation 11 and secure w...

Страница 37: ...ition of the roof the roof should be suitably strengthened Consult a structural engineer Each solar collector and its fittings weigh approximately 36 kg LCS 2 0 m2 collector or 41 kg NPT200 2 0 m2 col...

Страница 38: ...ned by an angle of inclination greater than the optimum angle If the angle of inclination varies by 20 from the optimum angle the solar collector will receive about 10 less total annual solar radiatio...

Страница 39: ...e is used in the collector circuit then a suitable length of bendable grade or hard drawn copper pipe is to be brazed to the end of the collector circuit pipe work at the connection points where a cop...

Страница 40: ...olar hot pipe connects to the solar collector for this open circuit system Refer to Warning Plumber Be Aware on page 41 Maximum height to collector s The maximum height of a solar Loline installation...

Страница 41: ...gh temperature water can flow from the solar collectors to the solar storage tank and also reduce pipe heat losses The insulated copper pipe work should be fixed at suitable locations to prevent or re...

Страница 42: ...authority requirements or on other occasions where the solar collector s and solar hot and solar cold pipes are installed prior to the solar storage tank such as on a building site Collector Circuit...

Страница 43: ...and return system in a building The benefits of solar gain will be significantly reduced If a circulated flow and return system is required refer to Circulated Hot Water Flow and Return System on page...

Страница 44: ...g the in series gas booster Refer to step 12 on page 36 Fit the wall bracket and secure the solar storage tank to the wall prior to the mounting of an in series gas booster to the solar storage tank R...

Страница 45: ...regulatory authority requirements must be made TEMPERATURE PRESSURE RELIEF VALVE The temperature pressure relief valve is supplied in the plastic bag with the solar control unit ground kit components...

Страница 46: ...75 mm and 150 mm If a drain line discharges into a tundish the drain line from the tundish must be not less than DN20 The drain line from a tundish must meet the same requirements as for a drain line...

Страница 47: ...d with power from the power outlet via the solar control unit A flexible 20 mm conduit is provided for the electrical cable from the solar control unit to the solar storage tank The conduit is connect...

Страница 48: ...CONNECTIONS ELECTRICAL 48 WIRING DIAGRAM SOLAR STORAGE TANK Solar Control Unit Anti Freeze Heating Unit A1 N 3 1 4 2 Hot sensor connection Cold sensor Differential Controller Frost Heating Unit...

Страница 49: ...operation of the circulator There is no provision for nor is adjustment to the solar control unit required Remove the packaging covers from the solar collector s Note If the service 3 way valve was no...

Страница 50: ...inuous flow gas booster for the procedure to check and adjust the preset outlet temperature if required Refer to the Owner s Guide and Installation Instructions supplied with the in series storage boo...

Страница 51: ...emitting a series of three 3 flashes particularly if the solar collector s were left uncovered during the final stages of the installation and commissioning procedure This indicates a temperature diff...

Страница 52: ...lating water through collector s 3 x red Hot sensor in collector short circuit 3 x green Circulating water through collector s power on for less than 48 hours 4 x red Hot sensor in collector open circ...

Страница 53: ...e DRAINING THE SOLAR COLLECTOR S To drain the solar collector s and the solar hot and solar cold pipes Cover the solar collector s with an opaque material Open a hot water tap and allow the water to r...

Страница 54: ...from the collector circuit or flushing of the solar collector s be conducted early in the morning within three 3 hours of sunrise when the sun is low in the sky The water temperature inside the solar...

Страница 55: ...55 This page is intentionally blank...

Страница 56: ...56 This page is intentionally blank...

Страница 57: ...57 This page is intentionally blank...

Страница 58: ...of the original warranty period will remain effective The replacement does not carry a new Rheem warranty 2 4 Where the water heater is installed outside the boundaries of a metropolitan area as defin...

Страница 59: ...upply the hot water demand in accordance with the guidelines in the Rheem water heater literature any resultant fault will not be covered by the Rheem warranty 3 WHAT IS COVERED BY THE RHEEM WARRANTY...

Страница 60: ...er heater or if that s unavailable the date of manufacture and serial number from the rating label on the water heater b Rheem will arrange for the water heater to be tested and assessed on site c If...

Отзывы: