Specifications
Model
RHP270-3805
RHP340-3805
Power Supply
220V
~
50Hz
Circuit Fuse - Model Number
50T T16AL250V
Circuit Fuse - Parameters
16A/250V
Rated heating volume*
3250 W
HP heating rated input
Power (watts)
900
Current (amps)
4.1
Auxiliary heating input
Power (watts)
2400
Current (amps)
10.9
Maximum
In
put
Power (watts)
3800
Current (amps)
17.3
Rated Hot water output (litres/hr
)
70
Water temperature setting (
o
C
)
30
~
65
(
Preset 55
)
Suitable ambient temperature (
o
C
)
-7
~
43
Refrigerant quantity
R134a (1.35 Kg)
Water Side
Heat exchanger type
Copper Pipe coiled outside the tank
Tank capacity (L)
270
340
Cold/ hot water connection
RP ¾”
/ 20
relief valve connection
RP ¾” / 20
Maximum Pressure (MPa)
0.85
Air Side
Heat exchanger type
Female fitting hydrophilic aluminium foil
Air outlet
Side Exhaust
Storage
Tank
Diameter (mm)
ø648
Height (mm
)
1815
2125
Net weight (kg
)
115
130
*Working conditions: Dry bulb temperature: 20
o
C, Wet bulb Temperature: 15
o
C,
Tank water inlet: 15
o
C, tank water outlet: 55
o
C.