Rheem 3805 Series Скачать руководство пользователя страница 6

 

 

P a g e

 | 

4

 

Precautions 

Please read these precautions carefully, failure to follow these instructions may damage your Heat 
Pump  water  heater  or  endanger  the  safety  of  persons  and  property  in  the  vicinity  of  the  water 
heater.     

This  water  heater  is  only  intended  to  be  operated  by  persons  who  have  the  experience  or  the 
knowledge and the capabilities to do so. This water heater is not intended to be operated by persons 
with reduced physical, sensory or mental capabilities i.e. the infirm, or by children. Children should 
be supervised to ensure they do not interfere with the water heater.   
 
The water heater must be directly connected to a 220 V AC (±10%) mains power supply. The water 
heater must be on its own circuit with an isolating switch installed at the switchboard. A secondary 
isolating switch may be installed within reach of the water heater.   

 

The removal of the access cover(s) will expose 220 Volt wiring. They must only be removed 
by a qualified technician.   

 
This  water  heater  can  deliver  water  at  temperatures  which  can  cause  scalding.  Check  the  water 
temperature before use, such as when entering a shower or filling a bath or basin, to ensure it will 
not cause scald injury.   

 

We recommend and it may also be  required by regulations that an approved temperature 

limiting device be fitted. This will ensure the water temperature does not exceed 50°C and 

the risk of scald injury will be reduced. 

 

Do not use 

aerosols, stain removers and household chemicals 

near the water heater whilst 

it is working. Gases from some aerosol sprays, stain removers and household chemicals are 
corrosive to the materials used in the heat pump system.   

 

Do not store swimming pool chemicals, household cleaners, etc near the water heater.   

 

Ensure the air inlet and outlet louvres are not obstructed in any way at any time. Do not lean 
any  objects  against  water  heater  and  ensure  all  trees  and  shrubbery  are  well  clear  of  air 
intakes and exhaust.   

 

Discharge  of  water  from  relief  valve  and  condensate  drain  is  normal  during  heat  pump 
operation therefore provision must be made to drain this water away. A suitable floor drain 
that enables water to be drained away to a safe location must be installed near the storage 
tank  location.  The  continual  presence  of  moisture  around  base  of  heater  will  lead  to 
premature failure. 

 

The water heater is suitable for both indoor and outdoor installation. Take care to ensure all 
electrical components are protected from effects of humidity and rain.   

 

The  power  supply  to  the  water  heater  must  not  be  switched  on  until  the  water  heater  is 
filled with water.   

 

Do not attempt to install, repair or remove the water heater, all work must be carried out by 

a qualified technician.   

Содержание 3805 Series

Страница 1: ...Guide and Installation Instructions Rheem Heat Pump Water Heater 3805 Series 270 340 Models This water heater must be installed and serviced by a qualified person Please leave this guide with the hous...

Страница 2: ......

Страница 3: ...ed for use in a single family domestic dwelling for the purpose of heating potable water The main features of the water heater include automatic operation whilst power and water supplies available sim...

Страница 4: ...ECV 12 RELIEF VALVE DRAIN 12 CONDENSATION DRAIN 13 REDUCING HEAT LOSSES 13 WATER SUPPLIED BY STORAGE TANK ON THE ROOF 13 ELECTRICAL CONNECTION 14 OPERATION AND USAGE 15 TO FILL AND TURN ON THE WATER H...

Страница 5: ...PANEL 21 USING HOT WATER 22 WIRING DIAGRAM 24 WARRANTY 25 1 HEAT PUMP WATER HEATER MODEL ERROR BOOKMARK NOT DEFINED 2 TERMS OF THE SOLAHART WARRANTY AND EXCLUSIONS TO IT ERROR BOOKMARK NOT DEFINED 3 W...

Страница 6: ...an approved temperature limiting device be fitted This will ensure the water temperature does not exceed 50 C and the risk of scald injury will be reduced Do not use aerosols stain removers and househ...

Страница 7: ...operation of the equipment isolate power supply promptly and contact the Service Department Do not attempt to repair the unit Operate the easing lever on the temperature pressure relief valve at least...

Страница 8: ...ter temperature setting o C 30 65 Preset 55 Suitable ambient temperature o C 7 43 Refrigerant quantity R134a 1 35 Kg Water Side Heat exchanger type Copper Pipe coiled outside the tank Tank capacity L...

Страница 9: ...P a g e 7...

Страница 10: ...P a g e 8 Dimensions MODEL A mm B mm RHP270 3805 1151 1815 RHP340 3805 1461 2125...

Страница 11: ...of the water heater Make sure the temperature pressure relief valve lever is accessible and the top and front cover air inlet and outlet louvres system controls and thermostat can be removed for servi...

Страница 12: ...n contact with potable water Connection Sizes Cold water inlet RP 20 English system Sealed cylindrical inner thread Hot water outlet RP 20 English system Sealed cylindrical inner thread TPR valve RP 2...

Страница 13: ...n union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater Hot Water Delivery This water heater can deliver water a...

Страница 14: ...f valve and expansion control valve if one is installed to carry the discharge clear of the water heater Connect the drain lines to the valves using disconnection unions The drain line from the valve...

Страница 15: ...e pipe work from the condensate drain should be as short as possible and fall all the way from the water heater with no restrictions It should have no more than three right angle bends in it The outle...

Страница 16: ...o a 220V AC 10 50 Hz mains power supply The water heater must be on its own circuit with an isolating switch installed at the switchboard A secondary isolating switch may be installed within reach of...

Страница 17: ...taps Close each tap as water flows freely from it Check the pipe work for leaks Switch on the electrical supply at the isolating switch to the water heater Program the remote controller Remote Contro...

Страница 18: ...F Press the ON OFF button to switch on off the system When the system is switched off the remote control will display the time only b Temperature Setting Switch on the system factory preset temperatur...

Страница 19: ...rature appears iii Press OK again Pxx Temperature of Evaporator Coil appears f System Component Checks i During the time delay phase at start up or when system is switched off press and hold the up bu...

Страница 20: ...Water Quality Poor water quality will have a detrimental effect on the water heater and its operation and or life expectancy If you are unsure of your water quality information can be obtained from y...

Страница 21: ...parts and cause them to fail Where the saturation index exceeds 0 40 the water is very scaling and warranty does not apply to the water heater In a scaling water supply the calcium carbonate is depos...

Страница 22: ...s not replaced at this time it should be inspected regularly from this time Check the electric heating unit for excessive calcium build up or corrosion and replace if necessary Check and inspect the h...

Страница 23: ...Failure and Solution Control Panel Failure Possible reason Solution Remote display is blank buttons do not work No power available Check power supply Over temperature device activated determine cause...

Страница 24: ...cian E10 displayed Ambient temperature is too low and the inlet water temperature is too low Auxiliary heating required Lack of refrigerant Refer to refrigeration technician Check pipe work TX valve R...

Страница 25: ...hand lever to discharge water repeat Replace T PR if necessary High water supply pressure Ask plumber to install pressure reduction valve Noise inside water heater or pipes It is normal for slight noi...

Страница 26: ...P a g e 24 Wiring Diagram...

Страница 27: ...nents are covered The period in which the fault must appear in order to be covered What coverage you receive All components Year 1 Replacement of the faulty component at exwork price ONLY The cylinder...

Страница 28: ......