14.4 Set Point Limits and Defaults
14.4.1
System Adjustments
14.4.2
Alarm Set Points
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
High Flow Alarm
0
900 (25.5)
500 (14.2)
SCFD
(SCMD)
High Outlet Pressure
Alarm LP UNITS*
0.6 (4.1)
0.31* (2.1)
20.0 (137.9)
7.50* (51.7)
10.0 (68.9)
7.50* (51.7)
PSI (KPa)
Low Outlet Pressure
Alarm LP UNITS*
0.5 (3.4)
0.30* (2.1)
19.9 (137.2)
7.49* (51.6)
2.0 (13.8)
0.30* (2.1)
PSI (KPa)
High Humidity
Alarm
3
15
10
%
YES
High Compressor
Last Run Time
Alarm
2:00
5:00
3:00
Minutes
High Cabinet
Temperature Alarm
120 (48.9)
Deg F (Deg C)
YES
Compressor Total
Run Time Alarm
8000
Hours
14.4.3
System Operations
Description
ON Value
OFF Value
Default
Value
Unit of
Measurement
Compressor
20.0 (137.9)
50.0 (344.7)
PSI (KPa)
Fan
90 (32)
80 (26.6)
Deg F (Deg C)
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
System Pressure
60.0 (414)
PSI (KPa)
Static Pressure
17.0 (117.2)
PSI (KPa)
Outlet Pressure
LP UNITS*
2.0 (13.78)
0.30* (2.1)
15.0 (103.4)
7.50* (51.7)
PSI (KPa)
Alarm Delay
OFF
ON
ON
Startup Delay
0
10
0
Seconds