3

 

TERMS

 

&

 

DEFINITIONS

 

3.1

 

Relative

 

Humidity

 

(RH)

  is  the  moisture 

content of the air relative to the maximum 

possible  moisture  content  at  the  current 
air  temperature.  RH  is  measured  in 

percent  (%).  100%  RH  represents 
saturation,  and  is  the  point  at  which 

condensation occurs. 
Since  RH  is  relative  to  temperature,  the 

RH  of  the  air  in  the  waveguide  or  cable 
will  fluxuate  with  the  changes  in  air 

temperature.  As  the  air  temperature 
increases,  RH  will  fall;  as  the  air 

temperature  decreases,  the  RH  will  rise. 
The air’s actual moisture content remains 

constant. 

3.2

 

Dew

 

Point

 

Temperature

 

(Td)

  is  the 

temperature  at  or  below  the  current 
temperature  at  which  the  air  would  be 

saturated with moisture (100% RH). Td is 
measured  in  the  same  unit  as  ambient 

temperature,  typically  Fahrenheit  or 

Celsius. 
Dew  point  temperature  is  not  affected  by 

air  temperature  fluxuations.  Instead,  it  is 
directly  linked  to  the  actual  moisture 

content  in  the  air.  For  that  reason,  dew 
point  temperature  is  the  measurement 

most  applicable  to  dehumidification 
processes. 
Dew  point  temperature  is  fairly  constant 
over  time.  Weather  systems  and  seasonal 

changes  are  the  primary  cause  of  dew 
point temperature fluxuation over time. 
When  dew  point  temperature  and 
ambient  air  temperature  are  equal,  then 

the  air  is  saturated  (100%  RH),  and 
condensation  can  form.  Therefore,  it  is 

important  to  keep  the  dew  point 
temperature  of  the  air  inside  the 

waveguide  or  cable  below  the  ambient 

temperature  outside  the  waveguide  or 
cable to avoid condensation. 

3.3

 

Dew

 

Point

 

Reduction

 

(Tdr)

  is  the 

reduction  of  the  dew  point  temperature 
that  results  from  the  dehumidification 

process.  The  larger  the  Tdr,  the  more 
efficient the dehumidification process is. 

3.4

 

Distribution

 

System

  is  the  system  of  air 

tubes,  distribution  manifolds,  valves,  and 

RF  lines  to  be  pressurized  with  dry  air 
from the dehydrator’s output fitting. 

3.5

 

Active

  dehydrator  operation  is  when  the 

unit’s  compressor  is  on  and  pressurized 

dry  air  is  being  supplied  from  the  unit’s 
output fitting. 

3.6

 

Run

 

Time

 is the time that the unit spends 

in  active  operation  to  pressurize  the 

distribution system. 

3.7

 

Standby

  dehydrator  operation  is  when 

the unit is energized but the compressor is 
not  on.  The  distribution  system  pressure 

is  in  the  unit’s  configured  operational 

range, and is being monitored by the unit’s 
control  board.  This  is  the  predominant 

operational condition. 

3.8

 

Duty

 

Cycle

 is the time in active operation 

vs.  standby  operation,  measured  in 
percent. 

 

 

 % =  

   100 

3.9

 

Lower

 

Operational

 

Pressure

 

(LOP)

  is 

the  configured  pressure  at  which  the 

dehydrator  will  switch  from  standby  to 
active  operation  to  re-pressurize  the 

system. 

3.10

 

Upper

 

Operational

 

Pressure

 

(UOP)

  is 

the  configured  pressure  in  psig  at  which 
the  dehydrator  will  switch  from  active  to 

standby operation. This is also the system 
pressure,  or  the  maximum  pressure 

desired in the distribution system. 

 

Содержание APD-D Series

Страница 1: ...602400011500 Revision C Radio Frequency Systems 200 Pond View Drive Meriden CT 06450 Ph 203 630 3311 Fax 203 634 2272 www rfsworld com Product Manual AUTOMATIC PRESSURIZATION DEHYDRATOR APD D Series ...

Страница 2: ...602400011500 Revision C Page 2 of 24 This Page Intentionally Left Blank ...

Страница 3: ... TERMS DEFINITIONS 7 4 OPERATION 8 5 CONTROLS AND INDICATORS 12 6 MAINTENANCE 15 7 REPLACEMENT PARTS AND ACCESSORIES 18 8 OPTION CONFIGURATION SOFTWARE UPGRADE 18 9 SPECIFICATIONS 20 10 MODEL CONFIGURATION 21 11 RUN TIME CALCULATIONS 22 12 TRANSMISSION LINE VOLUMES 23 13 CE DECLARATION OF CONFORMITY 24 ...

Страница 4: ...cted The APD D series dehydrators are designed for 120 230VAC use at 50 60Hz The AC Mains configuration must be 1 N PE meaning 3 conductors 1 1 Single phase Line power wire color black or brown 2 N Neutral phase return tied to Earth ground at the local power panel wire color blue or white 3 PE Protective Earth ground wire color green with yellow stripe or green ____________________________________...

Страница 5: ...ydrator is designed for free standing operation on its vibration isolating rubber feet The dehydrator should be placed on a firm level surface An accessory wall rack mount shelf is available for alternative mounting methods and locations The APD series dehydrator requires a minimum of 2 clearance on the sides and top for proper heat dissipation 2 4 Installation Procedure 2 4 1 Ensure that the site...

Страница 6: ...ve operation run time Possible Solution Run time to pressurize the distribution system may have been miscalculated Please recalculate the run time record the unit s model and serial numbers and contact RFS Support to reconfigure the run time alarm Symptom Run time exceeds 4 hours before distribution system reaches the configured upper operating pressure Possible Solution Check for leaks in the dis...

Страница 7: ...herefore it is important to keep the dew point temperature of the air inside the waveguide or cable below the ambient temperature outside the waveguide or cable to avoid condensation 3 3 Dew Point Reduction Tdr is the reduction of the dew point temperature that results from the dehumidification process The larger the Tdr the more efficient the dehumidification process is 3 4 Distribution System is...

Страница 8: ...gid line ir in the res that sure swing ng a high cular sieve put air 4 1 APD D Operation The deh automatic media rep units are service w and main The A performa environm moisture output ai environm performa maintena in the a dripping avoided The AP designed controlled climatogr environm area nal Climatog ydration s c with no placement capable of when proper ntained APD D ance is depe mental con pr...

Страница 9: ... will activate and re pressurize the system with dry air The unit will return to standby operation when the upper operational pressure is reached A dehydrator duty cycle of less than 5 is recommended Maximum continuous active operation must not exceed 4 hours Any leaks in the distribution system should be small enough to ensure that active operation does not occur more often than once every 48 hou...

Страница 10: ...lve will open to prevent an unsafe pressure condition The control board and the humidity and pressure sensors monitor the low pressure dry air output and adjust unit operation accordingly The system purge valve allows for periodic purge and repressurization of the waveguide or cable system This optional feature requires the humidity alarm option or system purge option to be installed and configure...

Страница 11: ...he need to replace the desiccant cylinders The humidity sensor requires air flow for accurate measurement In order to accurately measure the system air humidity level humidity monitoring is only active during pumping and purging cycles For this reason the system purge option is required when the humidity alarm option is present 4 4 3 Run Time Alarm The optional run time alarm can be used as a warn...

Страница 12: ...d COMPRESSOR yellow Illuminated when compressor is active and pressurized dry air is being supplied LOW PRESSURE red Illuminated when the system pressure has dropped below the low pressure alarm threshold HIGH PRESSURE red Illuminated when the system pressure has dropped below the low pressure alarm threshold This indicator is only active on models configured with the high pressure alarm option HU...

Страница 13: ...y protruding To reset the circuit breaker wait for at least one minute after the overload occurred then press the button back in The unit will resume normal operation Picture 5 2 APD D Series Rear Panel Connections 5 5 AC Mains Voltage Input The IEC C14 type AC Mains voltage input connector is located in the lower right corner of the rear panel The APD20 D and APD70 D are supplied with a 2 meter N...

Страница 14: ...ing air to the unit The fan is operational only when the unit is actively pumping At least 2 inches of clearance is required for proper cooling air flow 5 8 Alarm Port The alarm port allows for customer supplied remote monitoring equipment to monitor the dehydrator for configured alarms The alarms are provided using 1 Form C relays All alarm contacts are passive and power must be supplied external...

Страница 15: ...s 54852BE and SitePro GL610 6 MAINTENANCE If properly installed and operated the Dehydrator will not require any maintenance for the length of the warranty period After that the only preventative maintenance requirements are a check of the compressor s input air filter element and dust debris removal once per year 6 1 Taking the Unit Out of Service and Removing the Lid 6 1 1 Disconnect the input p...

Страница 16: ...placement the RTC date and time should be reset Refer to Picture 6 2 6 3 1 Remove the old battery by gently lifting the retaining clip The battery should slide out of the holder easily 6 3 2 Install the new battery by pushing it under the clip until it snaps into the holder ___________________________________________________________________________________________________ W A R N I N G The followi...

Страница 17: ...tart normally 6 4 Replacing the Lid Placing the Unit Back In Service 6 4 1 Refer to Picture 6 1 and Picture 6 2 Place the lid next to the unit fan down Connect the case fan connector to the control board s fan header wires facing in 6 4 2 Pivot the lid onto the unit making sure not to pull or bind the fan wires 6 4 3 Replace the lid screws Insert all loosely at first and then torque each screw to ...

Страница 18: ...Desiccant cylinder subassembly APD70 D APD72 D 18 30032091 Rubber bumper foot M6 stud All APD D Models 19 20041902 Site Ground Kit 6AWG crimp terminal All APD D Models 20 20040835 Wall Rack Mount shelf mounting hardware not included All APD D Models 21 10042341 Field Configuration Upgrade Kit All APD D Models 8 OPTION CONFIGURATION SOFTWARE UPGRADE The APD D Dehydrator can be upgraded in the field...

Страница 19: ...mes to indicate successful firmware update 8 1 3 The unit will then restart normally indicators light top to bottom then extinguish bottom to top The USB device can now be removed 8 1 4 To verify the upgrade process plug the upgrade USB device into a PC and open the UPDATE LOG file on the USB device The following is a sample of the file contents Picture 8 1 UPDATE LOG File a The log indicates succ...

Страница 20: ...1A Low Pressure Alarm Standard on all units Standard configurations Fixed at 0 5 psi 3 4 kPa below lower operational pressure Low Pressure configurations Fixed at 0 25 psig 1 7 kPa SIZE AND WEIGHT Dimensions H x W x D inches mm 9 5 x 13 5 x 9 5 242 x 343 x 242 Net Weight pounds kilograms 25 11 4 30 13 6 ENVIRONMENTAL Max Operational Altitude 5 psig feet meters 6 500 1 930 6 000 1 830 12 400 3 780 ...

Страница 21: ...602400011500 Revision C Page 21 of 24 10 MODEL CONFIGURATION ...

Страница 22: ...run time in minutes Volume of system in m3 ft3 gallons or liters Volume conversion factor to cubic feet 35 314 for Volume in cubic meters m3 1 0 for Volume in cubic feet ft3 0 1337 for Volume in gallons 0 0353 for Volume in liters Lower operational pressure psig where compressor starts Upper operational pressure psig where compressor stops Effective flow linearized average Dehydrator output flow C...

Страница 23: ...0 16 0 432 Commscope Andrew Elliptical Waveguide volumes Waveguide Type Liters per meter l m Cubic foot per foot ft3 ft EW17 6 60 0 0710 EW20 5 62 0 0605 EW37 1 96 0 0211 EW43 1 69 0 0182 EW52 1 045 0 0112 EW63 0 855 0 0092 EW64 0 725 0 0078 EW77 0 585 0 0063 EW85 0 39 0 0042 EW90 0 334 0 0036 EW127A 0 25 0 0027 EW132 137 0 167 0 0018 EW132 140 0 167 0 0018 EW132 144 0 167 0 0018 EIA Rectangular W...

Страница 24: ...Page 13 e 24 of 24 CE DECLA ARATION OF CONF FORMITY 60 02400011500 Revision C 0 C ...

Отзывы: