RF-BM-ND08
Shenzhen RF-star Technology Co., Ltd.
Page 11 of 19
3 Specifications
3.1 Recommended Operating Conditions
Functional operation does not guarantee performance beyond the limits of the conditional parameter values in the table
below. Long-term work beyond this limit will affect the reliability of the module more or less.
Table 3. Recommended Operating Conditions of RF-BM-ND08
Items
Condition
Min.
Typ.
Max.
Unit
Operating Supply Voltage
Battery Mode
1.7
3.3
3.6
V
Operating Temperature
/
-40
+25
+85
℃
Environmental Hot Pendulum
/
-20
+20
℃
/min
3.2 Handling Ratings
Table 4. Handling Ratings of RF-BM-ND08
Items
Condition
Min.
Typ.
Max.
Unit
Storage Temperature
Tstg
-40
+25
+125
℃
Human Body Model
HBM
±
4000
V
Moisture Sensitivity Level
2
Charged Device Model
±
750
V
3.3 Power Consumption
Table 5. Power Consumption
Event
Average Current
Testing Conditions / Remark
Sleeping
2.62 µA
EN disconnected
Broadcast
77.70 µA
Broadcast cycle: 200 ms
Broadcast
30.01 µA
Broadcast cycle: 500 ms
Broadcast
15.64 µA
Broadcast cycle: 1000 ms
Broadcast
8.90 µA
Broadcast cycle: 2000 ms
Broadcast
4.27 µA
Broadcast cycle: 5000 ms
Connection
72.80 µA
Connection cycle: 50 ms
Connection
38.28 µA
Connection cycle: 100 ms