background image

REMC0218GD

RF-LAMBDA USA LLC: 

www.rflambda.com

Sales: 

[email protected]

Technical: 

[email protected]

Rev 2. 06-25-2021 | Subject to change without notice 

Wideband EMC Benchtop Power Amplifier 

2GHz-18GHz

Electrical Specifications (T

A

=+25⁰C)

Parameter

Min

Typ

Max

Units

Frequency Range

2 – 18

GHz

Small Signal Gain

47

50

dB

Gain Flatness

±5

dB

Gain Variation Over Temperature (-40

⁰C

to +85

C)

±3

dB

Input VSWR

2

:1

*Output 1dB Compression Point (P1dB)

45

dBm

*Saturated Output Power (Psat)

47

dBm

Isolation S12 

60

dB

Supply Current (110V/ 220V AC) 

4

A

Efficiency at Psat

10

%

Weight 

22.53

lbs.

Impedance

50

Ohms

Input / Output Connectors

SMA-Female(Input)-N-Female(Output)

Product Description

The REMC0218GD is a wideband EMC power amplifier with a frequency 

range of 2 to 18GHz. 

The power output of this amplifier is 47dBm typical. The typical small signal 

gain is 50dB with a gain flatness of 

±

5 dB.

The power amplifier’s input connector is SMA-Female and output connector 

is N-Female. This product has a calibration feature which enables customer 

to obtain great performance through time and temperature changes. 

The operating temperature of this product is within -40 to +85

⁰C

.

Features

• Wideband EMC S Benchtop Power Amplifier

• Small Signal Gain 50dB Typical 

• Output Saturation Power 47dBm Typical

• Supply Voltage 110/220 VAC

• 50 Ohm Matched Input/Output

• Overvoltage Protection

• Overcurrent Protection 

• Auto Calibration 

Typical Applications

• Wireless Infrastructure

• Military and Aerospace Applications

• Test Instrumentation

• Radar Systems

• 5G Wireless Communications 

• Microwave Radio Systems

• TR Modules 

• Research and Development

• Cellular Base Stations

Содержание REMC0218GD

Страница 1: ...mplifier with a frequency range of 2 to 18GHz The power output of this amplifier is 47dBm typical The typical small signal gain is 50dB with a gain flatness of 5 dB The power amplifier s input connect...

Страница 2: ...14 I Test Condition Letter C 1 5 Hours Per Axis High Temperature Burn In Temperature 85 C for 72 Hours Shock 1 Weight 20g 50g half sine wave for 11ms Speed variation 3 44m s 2 Weight 20g 100g Half sin...

Страница 3: ...pment Specifications Front Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Rear Panel Instrument AC power supply switch Fuse Holder Main AC connector...

Страница 4: ...e error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is may be...

Страница 5: ...Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on front panel keypad to select 1 Calibrate calibrates the instruments 2 Frequency enters RF i...

Страница 6: ...drain current of the combining branches occurs Yes 8 PA input power Indicator PA input power is represented by voltage No 9 PA output power Indicator PA output power is represented by voltage No 10 P...

Страница 7: ...ions https rflambda com search_heatsink jsp Connector Torque Specifications https www rflambda com pdf Torque_Specifications pdf Random Vibration Test Standard https www rflambda com pdf rflambda_rand...

Страница 8: ...e degradation or loss of functionality What is not covered with warranty Each RF Lambda amplifier will go through power and temperature stress testing Since the die ICs or MMICs are fragile these are...

Отзывы: