6.3
Connecting the Cooling Water (only for MAF Motors)
Inflow (IN) and outflow (OUT) can be assigned at the user's dis‐
cretion. The assignment does not affect the performance data of
the motor.
Motor
MAF ...
Connection via …
Remark
Thread
Quick-action coupling
[Ø d
i
hose]
100 ... 130
G1/4"
9 mm
Select the connection type
acc. to the type code
160 ... 225
G1/2"
13 mm
Fig.6-14:
Overview of coolant connections
On delivery, the connection threads at the motor are covered with protective
stoppers. These protective stoppers may only be removed shortly before the
coolant lines are screwed in or the quick-action couplings are removed to
avoid the intrusion of dirt into the cooling system.
Cooling line connection threads
Overall size
MAF…
Connection
thread
Max. permissible depth
of engagement [mm]
Max. permissible tighten‐
ing range [Nm]
100 ... 130
G1/4"
14
18 ... 20
160 ... 225
G1/2"
18
27 ... 30
Fig.6-15:
Coolant connection thread, permissible tightening torques and thread
depths
Wrong tightening torques may destroy the
coolant connection threads on the motor!
NOTICE
Make absolutely sure not to exceed the permissible tightening torque of the
motor connections! Exceeding the tightening torque or depth of engagement
can lead to irreversible motor damage.
The motor-sided coolant connections are designed for coolant connection
threads with axial sealing.
Bosch Rexroth recommends to use connection threads which contain an O-
ring for axial sealing of the screw connection.
Sealing with hemp bred, teflon tape or conical screw unions is not considered
suitable as this kind of sealing can stress and/or even damage the connec‐
tion thread on the motor to an unreasonably high degree.
The machine manufacturer is responsible for the tightness of the
coolant connection and for testing and accepting it after installa‐
tion of the motor.
Furthermore, a regular test of correct condition of the coolant con‐
nection should be specified in the machine maintenance sched‐
ule.
Quick-action coupling
Another coolant connection variant is the quick-action coupling. It has a leak
protection at both sides and can be released even under full pressure of the
coolant system.
If a motor having this coolant connection is ordered, all parts of the quick-ac‐
tion coupling are included in the motor delivery. The user can choose from
Bosch Rexroth AG
DOK-MOTOR*-MAD/MAF****-IT01-EN-P
Rexroth IndraDyn A Asynchronous Motors MAD / MAF
44/67
Assembly
Содержание MAD100
Страница 12: ...60 15 Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF X 67...
Страница 20: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 18 67...
Страница 22: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 20 67...
Страница 30: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 28 67...
Страница 34: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 32 67...
Страница 50: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 48 67...
Страница 56: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 54 67...
Страница 58: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 56 67...
Страница 62: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 60 67...
Страница 64: ...Bosch Rexroth AG DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF 62 67...
Страница 69: ...Notes DOK MOTOR MAD MAF IT01 EN P Rexroth IndraDyn A Asynchronous Motors MAD MAF Bosch Rexroth AG 67 67...