8-18
Installation
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
8.5
Electrical Control Connectors
The control connectors are situated under the terminal cover of the
frequency converter.
Terminals:
Plugging or clamping connectors, are opened with a small screwdriver.
Maximum connection cross-section:
1.0mm
2
(AWG 26-14)
Relay = 1.5mm
2
(AWG 26-16)
Control cables:
run and shield separately from mains/motor cables
Control voltages:
5V
±
20%, max. 250mA
(short-circuit proof)
10V, max. 5mA, reference voltage for an ext.
potentiometer
15V
±
20%, max. 150mA, for supplying the dig.
inputs
analog output 0…10V, max. 20mA, for an ext.
indicator
Note:
AGND and DGND are signal common for analog or digital
inputs.
If applicable, 5V/15V can be picked off by several terminals.
The sum of the picked-off currents must not exceed
250mA/150mA.
X35:
Analog inputs and
outputs
+10V max. 5mA
0...10V or
0/4...20mA
X36:
Digital inputs and
power supply
R
i
approx. 4.5 k
Ω
+15V max. 150mA
+5V max. 250mA
11
12
14
16
17
AOUT
AIN 2
AIN 1
AGND/0V
VO +10V
21
22
23
24
25
42
40
41
I V
I V
S2 AIN 1
DIN 1
DIN 2
DIN 3
DIN 4
DIN 5
VO +15V
DGND/0V
VO +5V
S3 AIN 2
S2, S3:
Switch-over of analog
inputs AIN1 / AIN2
Power/voltage
command value
I = power 0/4...20mA
V = voltage 0...10V
Fig. 8-24:
Electrical control connection
Содержание IndraDrive Fc FCS01
Страница 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 237: ......