Input Channel Parameter
Input signal
Unit
Min
Typ.
Max
Allowed input voltage
V
-3
-
30
Logical 0 (Low)
V
-
-
5
Logical 1 (High)
V
15
-
-
Input current
mA
2
-
15
Impedance
kΩ
-
3.8
-
Filtering time
①
ms
-
> 3
-
Response time
②
ms
-
< 20
-
Tab. 19-6: Input channel parameter
①
: Filtering time means when a low time test pulse (as shown in fig-
ure below, "t
p
" is the filtering time) input to the channel, there is no
influence to the operation and indication of the device.
②
: Response time means time from the de-energization of each STO
input channel to the power semiconductor stage shut off the out-
puts of the device.