Installation 39/60
RE 91616-01-B/10.2014, A6VE Series 65 and 71,
Bosch Rexroth AG
6.
Check all pipes and hose lines and every combination of connecting pieces,
couplings or connecting points with hoses or pipes to ensure they are in
condition for safe working.
Relationship between direction of rotation and flow direction:
Clockwise rotation:
A
to
B
Counter-clockwise rotation:
B
to
A
7.4.9 Electrically connecting the axial piston unit
NOTICE
Short circuit in event of penetrating hydraulic fluid!
Fluid can penetrate the product and cause a short circuit!
▶
Do not install axial piston units with electric components (e.g. electric controls,
sensors) in a reservoir below the fluid level (inside-reservoir installation).
The machine/system manufacturer is responsible for the layout of the electric
control.
Electrically controlled axial piston units must be connected in accordance with the
electrical circuit diagram for the machine/system.
For axial piston units with electrical control and/or mounted sensors, please comply
with the details given in data sheets 91615 and 91616, e.g.:
•
the permissible voltage range
•
the permissible current
•
the correct connection
•
the recommended electrical control units
Exact details on the connector, type of protection and matching mating connector
can also be found in data sheets 91615 and 91616. The mating connector is not
included in the scope of delivery.
1.
Switch off power supply to the relevant system component.
2.
Electrically connect the axial piston unit (12 or 24 V). Before connection, check
that the connector including all seals are intact.
If necessary, you can change the connector orientation by turning the solenoid
housing. This is dependent on the connector version.
To do this, proceed as follows:
1.
Loosen the mounting nut (
1
) of the solenoid. To do this, turn the mounting nut
(
1
) one turn counter-clockwise.
2.
Turn the solenoid body (
2
) to the desired orientation.
3.
Retighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
Changing connector
orientation
1
2