14/60
General instructions on damage to property and the product
Bosch Rexroth AG
, A6VE Series 65 and 71, RE 91616-01-B/10.2014
3 General instructions on damage to
property and the product
The following instructions apply for chapters 6 to 14.
NOTICE
Danger from improper handling.
Product can be damaged.
▶
Do not expose the product to a non-permitted mechanical load.
▶
Never use the product as a handle or step.
▶
Do not place/lay any objects on the product.
▶
Do not strike the drive shaft of the axial piston unit.
▶
Do not set/place the axial piston unit on the drive shaft or fittings.
▶
Do not strike fittings (e.g., sensors or valves).
▶
Do not strike sealing surfaces (e.g. working line ports).
▶
Leave the protective covers on the axial piston unit until shortly before the lines
are connected.
▶
Disconnect all electrical connectors before performing electro-welding or
painting operations.
▶
Make certain that the electronic components (e.g., sensors) do not become
electrostatically charged (e.g., during painting operations).
Damage to equipment due to improper lubrication.
Product can be damaged or destroyed.
▶
Never operate the axial piston unit with insufficient hydraulic fluid. In particular,
make sure that the rotary group has sufficient lubrication.
▶
When commissioning a machine/system, make sure that the case interior and
the working lines of the axial piston unit are filled with hydraulic fluid and
remain filled during operation.
▶
Check the hydraulic fluid level in the motor housing regularly; if necessary,
recommission. With above-reservoir installation, the motor housing may drain
via the drain line after longer standstill periods (air enters via the shaft seal)
or via the working line (gap leakage). When switched on, the bearings are thus
insufficiently lubricated.
Mixing of hydraulic fluids.
Product can be damaged.
▶
Before installation, remove all fluids from the axial piston unit to prevent mixing
with the hydraulic fluid used in the machine/system.
▶
Any mixing of hydraulic fluids from different manufacturers or different types
from the same manufacturer is not generally permitted.