H1, S1, S2, S3: Diagnostic display, Reset key, Address switch
Fig. 5-70:
H1: Diagnostic display, S1: Reset key, S2, S3: Address switch
H1
Number of diagnostic messages (errors and operating states).
S1
•
Key for resetting diagnostic displays of errors
•
Key for updating firmware
S2, S3
Switch for setting the drive address.
Two decade switches are used to set the drive address. It can be set to
any number between 1 and 99.
Example:
Switch setting S3 = 9 (value of tens)
Switch setting S2 = 1 (value of ones)
Drive address = 9 * 10 + 1 = 91
Note:
The address is not set at delivery.
The setting of switches S2 and S3 depends on the model,
firmware and the drive address wanted.
see functional firmware description
Address switch S2, S3;
Drive address
|