![Rexroth Indramat BZM 01.3-01-07 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/rexroth-indramat/bzm-01-3-01-07/bzm-01-3-01-07_project-planning-manual_1449634135.webp)
ECODRIVE03 Drive Controllers
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
4-103
SV0200d1.Fh7
1: Quadrature-signals
2: Seperate signals for forward/ backward count
3: Count and direction signals
SM 1
SM 2
SM 1
SM 2
SM 2
SM 1
turning ccw
t1
t2
t3
t
L
turning ccw
turning cw
w
c
g
n
i
n
r
u
t
w
c
c
g
n
i
n
r
u
t
t2 5,6 µs
t3 5,6 µs
tL 2,8 µs
t1 1,4 µs
turning cw
t1
Fig. 4-174: Stepper motor interface types of control
•
Logic 1 is detected with a positive voltage difference of SM+ to SM-.
•
Logic 0 is detected with a negative voltage difference of SM+ to SM-.
•
To increase noise immunity the amplitude of the voltage difference
should equal at least 3.0 volts. The greater the voltage difference, the
better the noise immunity.
Controlling with the stepper
motor interface:
Control with differential signals:
|
(479) 422-0390