![REX RKF 130 Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/rex/rkf-130/rkf-130_general-information-manual_1449159106.webp)
RKF 130
Maintenance
Page 106 of 128
Version 1.1
5.
MAINTENANCE
5.1
CLEANING AND CLEANING PLAN
•
Safety instructions
The off button should be pressed before beginning with cleaning (4.2 Operating
elements/function).
-
The main switch should be set on position "0"
-
Caution when using a high-pressure cleaner (danger of damaging the electrical
and mechanical parts)
Never direct the abrasive blast cleaning on the following units:
-
Control panel (touch control)
-
Area of mechanical bearings
-
Other electrical devices, such as clamp or cable lead-ins, external device sockets
-
Louvre on the floor of the piston filler
-
All the visible seals
Do not process polished metal surfaces with abrasive medium, danger of eroding the anti-
corrosive.
Do not use any cleanser or cleaning agent containing metallic substance. Danger of eroding
the anti-corrosive.