The device has two sleep modes: sleep and deep sleep mode. While sleep is
disabled (value 0) module will never enter sleep mode, in sleep mode (value 1)
module reduces level of power usage by turning GNSS module to sleep, in deep
sleep mode (value 2) module turns GNSS module to sleep and switch GSM
module off (note, that DB3 Plug&Play do not receive SMS while in deep sleep).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.2.2 Sleep Timeout (ID=1001)
Sleep timeout is time after which DB3 Plug&Play goes to sleep or deep sleep if
other requirements are met. It is measured in minutes.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
3000
-
U8
9.2.3 Mode Switch Source (ID=1002)
The device can operate and change its working mode according to motion
detection source:
ignition (value 0), movement (value 1), GNSS (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.2.4 Ignition Source (ID=1003)
The device can operate and change its working mode according to motion
detection source: Power Voltage (value 0), Digital Input 1 (value 1), movement
(value 2).