9.8.4 I/O#1 Low level (ID=1303)
The parameter defines the low value of triggered I/O property. This parameter
is used to set thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-
2147483648
2147483647
0
I/O#1 property
parameter (ID=1300)
I/O#1 priority (ID=1301)
I/O#1 High level
(ID=1302)
I/O#1 logic operand
(ID=1304)
I/O#1 averaging length
(ID=1305)
S32
9.8.5 I/O#1 Logic Operand (ID=1304)
Parameter defines when event is sent: 0 – on range exit; 1 – on range entrance;
2 – both; 3 – monitoring; 4 – hysteresis.
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
4
3
I/O#1 property
parameter
(ID=1300)
I/O#1 priority (ID=1301)
I/O#1 High level
(ID=1302)
I/O#1 Low level
(ID=1303)
S8